OSHA Inspection: COLORADO STONE PRODUCTS OF TEXAS INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of COLORADO STONE PRODUCTS OF TEXAS INC. in 2025 COUNTRY CLUB DR, CARROLLTON, TX 75006 (NAICS 327390). OSHA activity number 339671117.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Colorado Stone Products of Texas INC. — free Get an email when a new federal OSHA severe-injury report for Colorado Stone Products of Texas INC. is published. One employer, no account, unsubscribe in one click.
Site address
2025 COUNTRY CLUB DR
City
CARROLLTON
State
TX
ZIP
75006
Mailing
2025 COUNTRY CLUB DR, CARROLLTON, TX 75006
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327390
Employees
142
Ownership type
A

8 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 2 instances 5 exposed
Issued
Jun 27, 2014
Penalty
Initial $3,600 · Current $5,800
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    Instance : a) This violation occurred on or about March 21, 2014 at a workplace located at 2025 Country Club Drive, Carrollton, Texas; in the maintenance shop, where at least three (3) employees used a drill press and were not protected from contacting the rotating drill bit.    Instance : b) This violation occurred on or about March 21, 2014 at a workplace located at 2025 Country Club Drive, Carrollton, Texas; in the mold making shop, where at least two (2) employees used a drill press and were not protected from contacting the rotating drill bit.
Recent events (2)
  • — I (S) $5800
  • — Z (S) $3600

1910.215 A04

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 27, 2014
Penalty
Initial $3,600 · Current $0 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one-eighth inch:     This violation occurred on or about March 21, 2014 at a workplace located at 2025 Country Club Drive, Carrollton, Texas; in the maintenance shop, where at least three (3) employees used a bench grinder that had one (1) missing work rest and an opening greater than one-eighth inch.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3600

1910.242 B

Other-than-serious 1 instance 4 exposed
Issued
Jun 27, 2014
Abate by
Jul 17, 2014
Penalty
Initial $3,600 · Current $500 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i. and effective chip guarding and personal protective equipment was not used:     This violation occurred on or about March 21, 2014 at a workplace located at 2025 Country Club Drive, Carrollton, Texas; in the maintenance shop, mold filling shop, and mold making shops where at least four (4) employees used compressed air at pressures greater than 30 p.s.i. for all static conditions.
Recent events (2)
  • — I (O) $500
  • — Z (S) $3600

1910.252 B02 III

Serious Gravity 5 1 instance 6 exposed
Issued
Jun 27, 2014
Penalty
Initial $3,600 · Current $1,500 Reduced
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields:    This violation occurred on or about March 21, 2014 at a workplace located at 2025 Country Club Drive, Carrollton, Texas; near the evaporator cooler adjacent to the mold breaking shop, where at least six (6) mold breaking employees were not protected from ultraviolet rays produced by nearby welding operations.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $3600

1910.253 B04 III

Other-than-serious 1 instance 3 exposed
Issued
Jun 27, 2014
Penalty
Initial $4,500 · Current $500 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:    This violation occurred on or about March 21, 2014 at a workplace located at 2025 Country Club Drive, Carrollton, Texas; in the maintenance shop back storage room, where  employees working in the maintenance shop were exposed to fire, explosion, and struck-by hazards where the employer did not ensure that oxygen cylinders were not stored near fuel-gas cylinders a minimum distance of 20 feet or by a noncombustible barrier at least 5 feet (1.5m) high having a fire-resistance rating of at least one-half hour.
Recent events (2)
  • — I (O) $500
  • — Z (S) $4500

1910.304 G05

Serious Gravity 5 2 instances 3 exposed
Issued
Jun 27, 2014
Penalty
Initial $4,500 · Current $5,800
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    Instance: a)This violation occurred on or about March 21, 2014 at a workplace located at 2025 Country Club Drive, Carrollton, Texas; in the maintenance shop, where at least three (3) employees used a wall mounted shop fan with the ground pin missing.     Instance: b)This violation occurred on or about March 21, 2014 at a workplace located at 2025 Country Club Drive, Carrollton, Texas; in the maintenance shop, where at least three (3) employees used a shop fan for ventilation with the ground pin missing.
Recent events (2)
  • — I (S) $5800
  • — Z (S) $4500

1910.305 G02 III

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 27, 2014
Penalty
Initial $3,600 · Current $0 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:    This violation occurred on or about March 21, 2014 at a workplace located at 2025 Country Club Drive, Carrollton, Texas; in the mold making shop, where at least one (1) employee used a hot iron knife that did not have strain relief causing a transmission of tension to joints and or terminal screws.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3600

1910.334 A02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 27, 2014
Penalty
Initial $4,500 · Current $0 Reduced
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service and an employee was using it before repairs and tests necessary to render the equipment safe were made:    This violation occurred on or about March 21, 2014 at a workplace located at 2025 Country Club Drive, Carrollton, Texas; in the mold breaking area next to the evaporator cooler, where at least one (1) employee was using a Lincoln arc welding machine that had damaged insulation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4500

View Colorado Stone Products of Texas INC.'s full OSHA safety record →