Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: J.B. ROOFING & CONSTRUCTION CORP.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of J.B. ROOFING & CONSTRUCTION CORP. in LOT 649 GALLANT FOX, ELGIN, IL 60124 (NAICS 238160). OSHA activity number 339671570.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J.B. Roofing & Construction Corp. — free Get an email when a new federal OSHA severe-injury report for J.B. Roofing & Construction Corp. is published. One employer, no account, unsubscribe in one click.
Site address
LOT 649 GALLANT FOX
City
ELGIN
State
IL
ZIP
60124
Mailing
730 BRIGHTON CIRCLE, PORT BARRINGTON, IL 60010
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

4 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 2 instances 2 exposed
Issued
May 13, 2014
Abate by
May 23, 2014
Penalty
Initial $1,760 · Current $1,056 Reduced
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury:        On or about April 9, 2014 at the above addressed jobsite, employees were using a pneumatic nail gun and were not wearing safety glasses, thereby exposing the employees to the hazards associated with eye injuries.   Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • — I (S) $1056
  • — Z (S) $1760

1926.451 G01 I

Serious Gravity 10 1 instance 1 exposed
Issued
May 13, 2014
Abate by
May 23, 2014
Penalty
Initial $3,080 · Current $1,848 Reduced
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system:    On or about April 9, 2014, at the above addressed jobsite, employees performing roofing operations from a ladder jack scaffold, 19.3 feet above the ground, did not utilize a personal fall arrest system, thereby exposing the employees to falls.     Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $1848
  • — Z (S) $3080

1926.1053 B01

Serious Gravity 5 2 instances 3 exposed
Issued
May 13, 2014
Abate by
May 23, 2014
Penalty
Initial $2,640 · Current $1,584 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to upper landing surfaces, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladders were used to gain access.     On or about April 9, 2014 at the above addressed jobsite, the portable ladders in the front and back of the house used to access to the roof did not extend at least three (3') feet above the upper landing surface, thereby exposing employees to the hazards associated with falls.   Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • — I (S) $1584
  • — Z (S) $2640

1926.501 B13

Repeat Gravity 10 1 instance 2 exposed
Issued
May 13, 2014
Abate by
May 23, 2014
Penalty
Initial $6,160 · Current $3,672 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system.      On or about April 9, 2014 at the above addressed jobsite, employees conducting roofing operations, 12-12.8 feet above the ground, were not protected from falling.   Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).        The J.B. Roofing & Construction Corp. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(10) which was contained in OSHA inspection number 714618, citation number 1, item number 1 and was affirmed as a final order on December 18, 2012, with respect to a workplace located at 321 Roosevelt Road, Glen Ellyn, IL .
Recent events (2)
  • — I (R) $3672
  • — Z (R) $6160

View J.B. Roofing & Construction Corp.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339671570.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.