COLUMBUS, OH —
OSHA Inspection: ALLIANCE CONSTRUCTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ALLIANCE CONSTRUCTION, INC. in 2045 POLARIS PARKWAY, COLUMBUS, OH 43240 (NAICS 236118). OSHA activity number 339671950.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALLIANCE CONSTRUCTION, INC.
- Site address
- 2045 POLARIS PARKWAY
- City
- COLUMBUS
- State
- OH
- ZIP
- 43240
- Mailing
- 600 ENTERPRISE DRIVE, LEWIS CENTER, OH 43035
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 15
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.350 A01
- Issued
- May 21, 2014
- Abate by
- Jun 11, 2014
- Penalty
- Initial $2,244 · Current $1,122 Reduced
General-duty citation text
29 CFR 1926.350(a)(1): Valve protection caps shall be in place and secured. a. In the first floor lobby area of the hotel where an Acetylene tank was stored, the valve protection cap was not in place, thereby exposing employees to struck-by and/or contact hazards.
Recent events (2)
- — I (S) $1122
- — Z (S) $2244
1926.350 A10
- Issued
- May 21, 2014
- Abate by
- Jun 11, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.350(a)(10): Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. a. In the first floor lobby area of the hotel where an Oxygen and Acetylene tanks were being stored, the tanks were stored 4 feet apart, thereby exposing employees to struck-by and/or contact hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.350 A11
- Issued
- May 21, 2014
- Abate by
- Jun 11, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.350(a)(11): Inside of buildings, cylinders shall be stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior. Cylinders should be stored in definitely assigned places away from elevators, stairs, or gangways. Assigned storage places shall be located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. Cylinders shall not be kept in unventilated enclosures such as lockers and cupboards. a. In the first floor lobby where oxygen and acetylene tanks were stored, the tanks were left unsecured in the open where they could be knocked over and damaged, thereby exposing employees to struck-by and/or contact hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B04 II
- Issued
- May 21, 2014
- Abate by
- Jun 11, 2014
- Penalty
- Initial $1,122 · Current $561 Reduced
General-duty citation text
29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface shall be protected from tripping in or stepping into or through holes (including skylights) by covers. a. In the north stairwell 4th floor landing where construction workers accessed the 4th floor, a hole had been cut through the floor for an HVAC duct and a gap of 4.5 inches x 30.5 inches was left exposed, exposing employees to a trip hazard. b. In the north stairwell 3rd floor landing where construction workers accessed the 4th floor, a hole had been cut through the floor for an HVAC duct and a gap of 4.5 inches x 30.5 inches was left exposed, exposing employees to a trip hazard.
Recent events (2)
- — I (S) $561
- — Z (S) $1122
1926.502 I03
- Issued
- May 21, 2014
- Abate by
- Jun 11, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(i)(3): All covers shall be secured when installed so as to prevent accidental displacement by the wind, equipment, or employees. a. In the north stairwell 2nd floor landing where construction workers accessed the 2nd floor, a hole had been cut through the floor for an HVAC duct and a gap of 4.5 inches x 30.5 inches was covered, but not secured, exposing employees to a trip hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.502 I04
- Issued
- May 21, 2014
- Abate by
- Jun 11, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(i)(4): All covers shall be color coded or they shall be marked with the word "HOLE" or "COVER" to provide warning of the hazard. Note: This provision does not apply to cast iron manhole covers or steel grates used on streets or roadways. a. In the north stairwell 2nd floor landing where construction workers accessed the 2nd floor, a hole had been cut through the floor for an HVAC duct and a gap of 4.5 inches x 30.5 inches was covered, but not marked with Hole or Cover, exposing employees to a trip hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Alliance Construction, INC.
View Alliance Construction, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236118)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339671950.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.