Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: PEACHTREE IN & OUT, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PEACHTREE IN & OUT, LLC in LOT #1 SPRING HILL PARKWAY, SMYRNA, GA 30080 (NAICS 238130). OSHA activity number 339672032.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Peachtree in & OUT, LLC for free Get an email when a new federal OSHA severe-injury report for Peachtree in & OUT, LLC is published. One employer, no account, unsubscribe in one click.
Site address
LOT #1 SPRING HILL PARKWAY
City
SMYRNA
State
GA
ZIP
30080
Mailing
926 SHILOH RIDGE RUN, KENNESAW, GA 30144
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
Private (A)

2 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 1 exposed
Issued
May 22, 2014
Penalty
Initial $3,080 · Current $3,080
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents.  (a) Roof trusses, new townhome construction located on Lot #1 Spring Hill Parkway, Smyrna, GA 30080: Employee was exposed to eye injuries while operating a pneumatic Hitachi (Model - NR83A) Framing Nail Gun at  120 PSI without safety glasses or other eye protection.
Recent events (1)
  • · Z (S) $3080

1926.501 B13

Repeat Gravity 10 1 instance 1 exposed
Issued
May 22, 2014
Abate by
Jun 4, 2014
Penalty
Initial $10,780 · Current $10,780
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:   (a) Roof, new townhome construction located on Lot #1 Spring Hill Parkway, Smyrna, GA 30080: Employee was exposed to falls while engaged in residential sheathing activities on a 6/12 pitched roof at eave heights of approximately 21-feet, 10-inches from the lower level without a fall protection system in place.   Peachtree In & Out, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 316078955, citation number 01, item number 001 and was affirmed as a final order on 04/23/2012, with respect to a workplace located at 4457 Wilkerson Place, Smyrna, GA 30082.
Recent events (1)
  • · Z (R) $10780

View Peachtree in & OUT, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339672032.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.