IDAHO FALLS, ID ·
OSHA Inspection: FAA TETON SYSTEM SUPPORT CENTER ADMINISTRATIVE OFFICE
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of FAA TETON SYSTEM SUPPORT CENTER ADMINISTRATIVE OFFICE in 1606 BENNETT AVE, IDAHO FALLS, ID 83401 (NAICS 921190). OSHA activity number 339672982.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 1606 BENNETT AVE
- City
- IDAHO FALLS
- State
- ID
- ZIP
- 83401
- Mailing
- 1606 BENNETT AVE, IDAHO FALLS, ID 83401
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 921190
- Employees
- 10
- Ownership type
- Federal government (D)
Citations
2 citations on file for this inspection.
1926.1101 F02 I
- Issued
- Jun 11, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1101(f)(2)(i): Each employer who has a workplace or work operation covered by this standard did not ensure that a "competent person" conduct an exposure assessment immediately before or at the initiation of the operation to ascertain expected exposures during that operation or workplace. a) The employer did not conduct an initial exposure assessment for potential asbestos exposure during the installation of emergency egress lighting. The employer disturbed asbestos containing wall surfacing material (2% Chysotile), and an exposure assessment had not been completed beforehand to plan for appropriate control systems and abatement measures. Abatement was completed for this item.
Recent events (1)
- · Z (S) $0
1926.1101 G09
- Issued
- Jun 11, 2014
- Abate by
- Jul 29, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1101(g)(9): Class III asbestos work was not conducted using engineering and work practice controls which minimize the exposure to employees performing the asbestos work and to bystander employees. a) Class III asbestos work was conducted in the Teton SSC during the installation of emergency egress lighting, and procedures to protect bystander employees from the hazards of asbestos were not implemented. b) Employees were required to remove equipment from the Teton SSC during the office shutdown before a negative assessment for asbestos exposure had been completed. These employees were not wearing personal protective equipment to protect themselves from the potential hazards of asbestos. Abatement certification is required for this item.
Recent events (1)
- · Z (S) $0
More inspections in this industry (NAICS 921190)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339672982.