Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DUCOMMUN AEROSTRUCTURES, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of DUCOMMUN AEROSTRUCTURES, INC. in 3333 MAIN ST., PARSONS, KS 67357 (NAICS 336413). OSHA activity number 339673980.

Watch Ducommun Aerostructures, INC. — free Get an email when a new federal OSHA severe-injury report for Ducommun Aerostructures, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3333 MAIN ST.
City
PARSONS
State
KS
ZIP
67357
Mailing
3333 MAIN ST., PARSONS, KS 67357
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336413
Employees
220
Ownership type
A

3 citations on file for this inspection.

1910.303 B02

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3000.00 · Current $2100.00 Reduced
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.  Employees working in the Machine Shop Blending area were exposed to electrical shock hazards in that an electrical drop box used to provide power connections was not certified for the application.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3000

1910.305 B02 I

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  Employees working in the Machine Shop Blending area were exposed to electrical shock hazards in that an electrical drop box used to provide power connections had a knock out missing.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  Employees working in the Machine Shop Blending area were exposed to electrical shock hazards in that an electrical drop box used to provide power connections did not have a functional stress relief on the electrical line entering the drop box.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View DUCOMMUN AEROSTRUCTURES, INC.'s full OSHA safety record →