PELHAM, AL —
OSHA Inspection: RESEARCH SOLUTIONS GROUP, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of RESEARCH SOLUTIONS GROUP, INC. in 402 INDUSTRIAL PARK DRIVE, PELHAM, AL 35124 (NAICS 325188). OSHA activity number 339676215.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RESEARCH SOLUTIONS GROUP, INC.
- Site address
- 402 INDUSTRIAL PARK DRIVE
- City
- PELHAM
- State
- AL
- ZIP
- 35124
- Mailing
- 100 TONY HOLMES DRIVE, PELHAM, AL 35124
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325188
- Employees
- 50
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.134 E01
- Issued
- Aug 12, 2014
- Penalty
- Initial $0 · Current $0
1430
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) On or about 04/15/14 - Hydrochloric (Muriatic) acid transfer point, an employee required to use a 3M full face respirator during transfer of hydrochloric acid from tanker trucks to drums had not been provided a medical evaluation.
Recent events (1)
- — Z (O) $0
1910.134 F02
- Issued
- Aug 12, 2014
- Penalty
- Initial $0 · Current $0
1430
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: a) On or prior to 4/15/14 - Hydrochloric (Muriatic) acid transfer point, an employee was not provided with a fit test prior to use of a 3M full face respirator during transfer of hydrochloric acid from tanker trucks to drums.
Recent events (1)
- — Z (O) $0
More inspections at Research Solutions Group, INC.
View Research Solutions Group, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325188)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339676215.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.