Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RESEARCH SOLUTIONS GROUP, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of RESEARCH SOLUTIONS GROUP, INC. in 402 INDUSTRIAL PARK DRIVE, PELHAM, AL 35124 (NAICS 325188). OSHA activity number 339676215.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Research Solutions Group, INC. — free Get an email when a new federal OSHA severe-injury report for Research Solutions Group, INC. is published. One employer, no account, unsubscribe in one click.
Site address
402 INDUSTRIAL PARK DRIVE
City
PELHAM
State
AL
ZIP
35124
Mailing
100 TONY HOLMES DRIVE, PELHAM, AL 35124
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325188
Employees
50
Ownership type
A

2 citations on file for this inspection.

1910.134 E01

Other-than-serious 1 instance 1 exposed
Issued
Aug 12, 2014
Penalty
Initial $0 · Current $0

Hazardous substances 1430

29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  a) On or about 04/15/14 - Hydrochloric (Muriatic) acid transfer point, an employee required to use a 3M full face respirator during transfer of hydrochloric acid from tanker trucks to drums had not been provided a medical evaluation.
Recent events (1)
  • — Z (O) $0

1910.134 F02

Other-than-serious 1 instance 1 exposed
Issued
Aug 12, 2014
Penalty
Initial $0 · Current $0

Hazardous substances 1430

29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:  a) On or prior to 4/15/14 - Hydrochloric (Muriatic) acid transfer point, an employee was not provided with a fit test prior to use of a 3M full face respirator during transfer of hydrochloric acid from tanker trucks to drums.
Recent events (1)
  • — Z (O) $0

View Research Solutions Group, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339676215.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.