DAHLONEGA, GA —
OSHA Inspection: REFRIGIWEAR, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of REFRIGIWEAR, INC. in 54 BREAKSTONE DRIVE, DAHLONEGA, GA 30533 (NAICS 315228). OSHA activity number 339676264.
Where did this inspection happen?
- Establishment
- REFRIGIWEAR, INC.
- Site address
- 54 BREAKSTONE DRIVE
- City
- DAHLONEGA
- State
- GA
- ZIP
- 30533
- Mailing
- 54 BREAKSTONE DRIVE, DAHLONEGA, GA 30533
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 315228
- Employees
- 125
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.219 A03
- Issued
- Abate by
- Penalty
- Initial $3443.00 · Current $2066.00 Reduced
General-duty citation text
29 CFR 1910.219(a)(3): The sides and face sections nip points of the drive belt(s) and pulley(s) of textile machinery were not guarded by a guard which extended at least six inches beyond the rim of the pulley on the in-running and off-running sides of the belt and at least two inches away from the rim and face of the pulley in all other directions: a) Refrigiwear, Inc., Dahlonega, GA - In the prep area, the ingoing nip point on the top section of the drive belt and pulley of the Juki LH 1152-4 model #H01118 was not guarded, on or about 4/15/14. b) Refrigiwear, Inc., Dahlonega, GA - In the prep area, the ingoing nip point on the top section of the drive belt and pulley of the Juki LH 1152-5 model #H01771 was not guarded, on or about 4/15/14. c) Refrigiwear, Inc., Dahlonega, GA - In the prep area, the ingoing nip point on the top section of the drive belt and pulley of the Juki LH 1152-5 model #K01273 was not guarded, on or about 4/15/14. d) Refrigiwear, Inc., Dahlonega, GA - In the prep area, the ingoing nip point on the top section of the drive belt and pulley of the Juki DDL 555-5 model #D96404 was not guarded, on or about 4/15/14. e) Refrigiwear, Inc., Dahlonega, GA - In the prep area, the ingoing nip point on the top section of the drive belt and pulley of the Juki DLN 415-5 was not guarded, on or about 4/15/14. f) Refrigiwear, Inc., Dahlonega, GA - In the prep area, the ingoing nip point on the top section of the drive belt and pulley of the Singer 211W151 model #WL789655 was not guarded, on or about 4/15/14. g) Refrigiwear, Inc., Dahlonega, GA - In the prep area, the ingoing nip point on the top section of the drive belt and pulley of the Singer 212G140 model #PE47761 was not guarded, on or about 4/15/14. h) Refrigiwear, Inc., Dahlonega, GA - In the prep area, the ingoing nip point on the top section of the drive belt and pulley of the Consew model #745R30 was not guarded, on or about 4/15/14.
Recent events (2)
- — I (S) $2065.8
- — Z (S) $3443
More inspections at REFRIGIWEAR, INC.
DAHLONEGA, GA—2011-11-15 00:00:00
REFRIGIWEAR INC.
DAHLONGA, GA—1991-10-23 00:00:00
REFRIGIWEAR, INC.
Inwood, NY—1973-03-09 00:00:00
REFRIGIWEAR INC
Inwood, NY—1972-11-27 00:00:00
REFRIGIWEAR INC
View REFRIGIWEAR, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 315228)
PORTLAND, OR—2020-02-26 00:00:00
317727069 - SETTLEMIERS AWARD JACKETS INC
ANNAPOLIS, MD—2014-01-15 00:00:00
STARBUS LTD
SALEM, OR—2012-09-11 00:00:00
WATERSHED LLC
SALEM, OR—2012-09-11 00:00:00
WATERSHED LLC
TROY, NY—2012-08-06 00:00:00
STANDARD MANUFACTURING CO. INC.
More inspections in GA
GREENSBORO, GA—2026-07-16
PURE BEAUTY FARMS, INC.
FOREST PARK, GA—2026-07-16
POLYNT COMPOSITES USA INC.
AUGUSTA, GA—2026-07-16
GF CASTING SOLUTIONS AUGUSTA, LLC
CHAMBLEE, GA—2026-07-16
U.S. DEPARTMENT OF TREASURY
DECATUR, GA—2026-07-15
PALLETS ACQUISITION LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339676264.