CLUTE, TX —
OSHA Inspection: INFINITY CONSTRUCTION SERVICES LP
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of INFINITY CONSTRUCTION SERVICES LP in 622 COMMERCE, CLUTE, TX 77531 (NAICS 238990). OSHA activity number 339677114.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INFINITY CONSTRUCTION SERVICES LP
- Site address
- 622 COMMERCE
- City
- CLUTE
- State
- TX
- ZIP
- 77531
- Mailing
- 622 COMMERCE ST., CLUTE, TX 77531
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 110
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.134 I07
- Issued
- Sep 12, 2014
- Abate by
- Sep 24, 2014
- Penalty
- Initial $5,500 · Current $4,950 Reduced
General-duty citation text
29 CFR 1910.134(i)(7): For oil-lubricated compressors, the employer shall use a high-temperature or carbon monoxide alarm, or both, to monitor carbon monoxide levels. When only high-temperature alarms are used, the air supply shall be monitored at intervals sufficient to prevent carbon monoxide in the breathing air from exceeding 10 ppm. At 622 Commerce St. Clute, TX; on or about April 15, 2014, the employer did not monitor the air supply from an oil lubricated compressor that was only equipped with a high temperature alarm, employees to an asphyxiation hazard.
Recent events (3)
- — F (O) $4950
- — C (S) $5500
- — Z (S) $5500
1910.134 I05 III
- Issued
- Sep 12, 2014
- Abate by
- Sep 24, 2014
- Penalty
- Initial $5,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.134(i)(5)(iii): The compressor's sorbent bed and filters were not maintained and replaced or refurbished periodically as instructed by the manufacturer: At 622 Commerce St. Clute, TX; at the outside blast area, the Bullard 41 series airline filter was not maintained according to manufacturer specifications, exposing employees to inhalation and asphyxiation hazards.
Recent events (3)
- — F (S) $0
- — C (S) $5500
- — Z (S) $5500
1910.134 I05 IV
- Issued
- Sep 12, 2014
- Abate by
- Sep 24, 2014
- Penalty
- Initial $5,500 · Current $4,950 Reduced
General-duty citation text
29 CFR 1910.134(i)(5)(iv): The employer did not ensure that the person authorized to perform the necessary sorbent bed and filter changes filled out a tag indicating by the signature and date that maintenance changes were performed: At 622 Commerce St. Clute, TX; at the outside blast area, the authorize employee did not ensure that a tag was filled out indicating that filter maintenance was performed, exposing employees to inhalation and asphyxiation hazards.
Recent events (3)
- — F (O) $4950
- — C (S) $5500
- — Z (S) $5500
1910.215 B09
- Issued
- Sep 12, 2014
- Abate by
- Sep 24, 2014
- Penalty
- Initial $4,400 · Current $3,960 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch. At 622 Commerce St., Clute, TX; a DeWalt DW756 6 inch bench grinder, SN: 2011 50-YL64693s was used where the distance between the wheel and periphery member at the top exceeded one fourth of an inch, exposing employees to struck by hazards.
Recent events (3)
- — F (O) $3960
- — C (S) $4400
- — Z (S) $4400
1910.303 B01
- Issued
- Sep 12, 2014
- Abate by
- Sep 24, 2014
- Penalty
- Initial $5,500 · Current $4,950 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Examination. Electric equipment was not free from recognized hazards that are likely to cause death or serious physical harm to employees. undefined : At 622 Commerce St. Clute, TX; in the south fabrication shop, an electrical cord connected to a control pedal for a welding machine was damaged, exposing employees to electrical hazards.
Recent events (3)
- — F (O) $4950
- — C (S) $5500
- — Z (S) $5500
1910.305 F01
- Issued
- Sep 12, 2014
- Abate by
- Sep 24, 2014
- Penalty
- Initial $5,500 · Current $4,950 Reduced
General-duty citation text
29 CFR 1910.305(f)(1): Conductors used for general wiring were not insulated: At 622 Commerce St. Clute, TX; the employer failed to insulate conductors behind the Disa blast machine, this exposed employees to electrical hazards. At 622 Commerce St. Clute, TX; the employer did not insulate conductors on the Disa Blast Machine, Unknown Serial #, exposing employees to electrical hazards.
Recent events (3)
- — F (O) $4950
- — C (S) $5500
- — Z (S) $5500
1910.334 A02 I
- Issued
- Sep 12, 2014
- Abate by
- Sep 24, 2014
- Penalty
- Initial $5,500 · Current $4,950 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): At 622 Commerce St. Clute, TX; at the south fabrication shop, electrical cord was not inspected and was used with damage to the outer jacket insulation, exposing employees to electrical hazards.
Recent events (3)
- — F (O) $4950
- — C (S) $5500
- — Z (S) $5500
1910.134 D01 III
- Issued
- Sep 12, 2014
- Abate by
- Sep 24, 2014
- Penalty
- Initial $1,100 · Current $990 Reduced
General-duty citation text
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form: At 622 Commerce St. Clute, TX; on or about April 15, 2014, at the receiving shop, the employer did not make reasonable assessment of exposure to silica, exposing employees to an inhalation hazard.
Recent events (3)
- — F (O) $990
- — C (O) $1100
- — Z (O) $1100
1910.1200 H03 II
- Issued
- Sep 12, 2014
- Abate by
- Sep 24, 2014
- Penalty
- Initial $1,100 · Current $990 Reduced
General-duty citation text
29 CFR 1910.1200(h)(3)(ii): Employee training did not include the physical and health hazards of the chemicals in the work area: At 622 Commerce St. Clute, TX; at the receiving shop, the employer did not notify employees of the presence and dangers of silica, exposing employees to inhalation hazards.
Recent events (3)
- — F (O) $990
- — C (O) $1100
- — Z (O) $1100
More inspections at Infinity Construction Services LP
View Infinity Construction Services LP's full OSHA safety record →
More inspections in this industry (NAICS 238990)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339677114.