Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,195,903Inspections Most recent open 2026-08-18 Last loaded 2026-08-21

OSHA Inspection: REGINO CANALES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of REGINO CANALES in 1007 CARISSA HOLLY DR, CONROE, TX 77384 (NAICS 238140). OSHA activity number 339681934.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Regino Canales for free Get an email when a new federal OSHA severe-injury report for Regino Canales is published. One employer, no account, unsubscribe in one click.
Establishment
REGINO CANALES
Site address
1007 CARISSA HOLLY DR
City
CONROE
State
TX
ZIP
77384
Mailing
3789 CROCKETT MARTIN RD, CONROE, TX 77306
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
2
Ownership type
Private (A)

5 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 1 instance 2 exposed
Issued
May 20, 2014
Abate by
May 22, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.451(b)(1): 29 CFR 1926.450(b)(1):  Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports.    The employer does not ensure that each platform on all working levels of scaffolds was fully planked or decked between the front uprights and the guardrail supports.  This violation was observed on or about April 15, 2014 when an employee was exposed to a fall hazard while doing masonry work form the second level of a scaffold which was not fully planked.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all working levels of scaffolds are fully planked or decked between the front uprights and the guardrail supports.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1926.451 C02

Serious Gravity 5 1 instance 2 exposed
Issued
May 20, 2014
Abate by
May 22, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates, mud sills or other adequate firm foundation.    The employer does not ensure that scaffold poles, legs, posts, frames, or uprights bear on base plates, mud sills or other adequate firm foundation.  This violation occurred on or about April 15, 2014 when employees were exposed to a fall hazard while doing masonry work from the second level of a scaffold that did not bear on base plates, mud sills or other adequate firm foundation.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all employees work from a scaffold that bears on base plates, mud sills or other adequate firm foundation.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1926.451 E01

Serious Gravity 5 1 instance 2 exposed
Issued
May 20, 2014
Abate by
May 22, 2014
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Cross braces were used as a means of access.    The employer does not ensure that employees are protected from falling while accessing a scaffold.  This violation occurred on or about April 15, 2014 when an employee was exposed to a fall hazard while doing masonry work from the second level of a scaffold without adequate access.      Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that employees have proper access to the scaffold platform.
Recent events (2)
  • · I (S) $960
  • · Z (S) $1600

1926.451 G01

Serious Gravity 10 1 instance 2 exposed
Issued
May 20, 2014
Abate by
May 22, 2014
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level.    The employer does not ensure that employees are protected from falling while working on a scaffold.  This violation occurred on or about April 15, 2014 when employees were exposed to a fall hazard greater than 10 feet while doing masonry work from the second level of a scaffold without fall protection.        Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that employees are protected from falls greater than ten feet.
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2800

1926.452 C02

Serious Gravity 5 1 instance 2 exposed
Issued
May 20, 2014
Abate by
May 22, 2014
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally.    The employer does not ensure that tubular welded frames and panels were braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally. This violation occurred on or about April 15, 2014 when employees were exposed to a fall hazard while doing masonry work from the second level of a scaffold that did not have cross braces.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all scaffolds have cross braces.
Recent events (2)
  • · I (S) $960
  • · Z (S) $1600

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339681934.