LONDON, OH —
OSHA Inspection: NISSEN CHEMITEC AMERICA
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of NISSEN CHEMITEC AMERICA in 350 EAST HIGH ST, LONDON, OH 43140 (NAICS 326199). OSHA activity number 339683112.
Where did this inspection happen?
- Establishment
- NISSEN CHEMITEC AMERICA
- Site address
- 350 EAST HIGH ST
- City
- LONDON
- State
- OH
- ZIP
- 43140
- Mailing
- 350 EAST HIGH ST, LONDON, OH 43140
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 385
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.178 L04 III
- Issued
- Abate by
- Penalty
- Initial $2550.00 · Current $1785.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance shall be conducted at least once every three years. a. At the workplace, employees who were authorized to operate a forklift were not evaluated every 3 years to prevent a struck by accident.
Recent events (2)
- — I (S) $1785
- — Z (S) $2550
1904.29 B01
- Issued
- Abate by
- Penalty
- Initial $850.00 · Current $595.00 Reduced
General-duty citation text
29 CFR 1904.29(b)(1): What do I need to do to complete the OSHA 300 Log? You must enter information about your business at the top of the OSHA 300 Log, enter a one or two line description for each recordable injury or illness, and summarize this information on the OSHA 300-A at the end of the year. Located at Nissen Chemitec America in London, Ohio: a. On the 2014 OSHA 300 Log the employer did not provide all information required in Column F such as the actual injury, the cause of injury and the body part affected.
Recent events (2)
- — I (O) $595
- — Z (O) $850
1910.147 C06 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection. a. At the workplace, the employer did not certify that periodic inspections of the energy control procedures were performed to ensure that the procedure and the requirements of the standard are being followed.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 326199)
LAWRENCEVILLE, GA—2026-07-16 00:00:00
REHRIG PACIFIC COMPANY
ERIE, PA—2026-07-14 00:00:00
CAPLUGS, LLC
WHATELY, MA—2026-07-13 00:00:00
G & W PRECISION
SANTA ROSA, CA—2026-07-13 00:00:00
WESTERN FIBERGLASS INC.
CONNEAUT, OH—2026-07-13 00:00:00
CONTINENTAL STRUCTURAL PLASTICS
More inspections in OH
DAYTON, OH—2026-07-17 00:00:00
TEKNOL, INC.
PAYNE, OH—2026-07-16 00:00:00
LIPPERT
SUGARCREEK, OH—2026-07-16 00:00:00
PROVIA
CINCINNATI, OH—2026-07-16 00:00:00
GREENACRES FOUNDATION
WELLINGTON, OH—2026-07-16 00:00:00
WHIRLAWAY CORPORATION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339683112.