Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: AMERICA'S REMANUFACTURING CO.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AMERICA'S REMANUFACTURING CO. in 1840 GORDON HWY, AUGUSTA, GA 30904 (NAICS 335210). OSHA activity number 339688525.

Watch America'S Remanufacturing CO. — free Get an email when a new federal OSHA severe-injury report for America'S Remanufacturing CO. is published. One employer, no account, unsubscribe in one click.
Site address
1840 GORDON HWY
City
AUGUSTA
State
GA
ZIP
30904
Mailing
1840 GORDON HWY, AUGUSTA, GA 30904
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335210
Employees
149
Ownership type
A

10 citations on file for this inspection.

1910.22 A01

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2700.00 · Current $1620.00 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.  a) Plant - On or about 04/17/14 and at times prior thereto the employer did not maintain the men and women restrooms in a clean and sanitary condition.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700

1910.36 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3600.00 · Current $2160.00 Reduced
29 CFR 1910.36(b)(2): More than two exit routes were not available in the workplace where the number of employees, the size of the building, its occupancy, or the arrangement of the workplace was such that all employees would not be able to evacuate safely during an emergency:  a) Warehouse - On or about 04/17/14 and at times prior thereto the 49,851 sq. ft. core storage area had a single free emergency exit door.  A second door was blocked by merchandise boxes and was not included in the emergency evacuation plan.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2160
  • — Z (S) $3600

1910.37 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3600.00 · Current $2160.00 Reduced
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  a) Warehouse - On or about 04/17/14 and at times prior thereto the door in the Receiving Breakdown Area discharging outside the building did not have an EXIT sign.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $2160
  • — Z (S) $3600

1910.147 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4500.00 · Current $2700.00 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:(  a) Plant - On or about 04/17/14 and at times prior thereto employees performed maintenance and repairs of equipment including (but not limited to) the Hobart dishwasher machines and the Gardner-Denver rotary screw compressor. The employer did not establish a program for the control of hazardous energy to protect workers from accidental contact with electrical energy and compressed air.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4500

1910.303 F02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4500.00 · Current $2700.00 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  a) Plant - On or about 04/17/14 and at times prior thereto disconnect switch boxes and dead-front panels exhibited misleading labels affixed by a previous manufacturing company established in the same building, in unrelated wood-working activity.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4500

1910.305 B01 II

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $4500.00 · Current $2700.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  a)  Plant - On or about 04/17/14 and at times prior thereto the dead front panel labeled "Feed Rails Hot Water Heater Plant N.W. 220 V" had five unused openings, exposing employees to accidental contact with live parts.  b) Plant - On or about 04/17/14 and at time prior thereto the dead front panel labeled "No 5" had one unused opening, exposing employees to accidental contact with live parts.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4500

1910.1200 E01

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $3600.00 · Current $2160.00 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  a) Plant - On or about 04/17/14 and at times prior thereto employees cleaned, repaired, and assembled used/returned vacuum cleaners and came in contact with chemicals including (but not limited to) concentrated sodium hypochlorite bleach and liquefied petroleum gas  (LPG) in cylinders. The employer did not develop and implement a written Hazard Communication Program.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $2160
  • — Z (S) $3600

1910.1200 G01

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use:  a) Plant - On or about 04/17/14 and at times prior thereto employees cleaned, repaired, and assembled used/returned vacuum cleaners and came in contact with chemicals including (but not limited to) concentrated sodium hypochlorite bleach and liquefied petroleum gas (LPG) in cylinders. The employer did not maintain copies of the safety data sheets at the workplace.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H01

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a) Plant - On or about 04/17/14 and at times prior thereto employees cleaned, repaired, and assembled used/returned vacuum cleaners and came in contact with chemicals including (but not limited to) concentrated sodium hypochlorite bleach and liquefied petroleum gas  (LPG) in cylinders. The employer did not train the employees in relation to the  Hazard Communication Program, the hazardous properties of the chemicals at the workplace, and the Globally Harmonized System of Classification and Labeling of Chemicals (GHS).  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 D01 III

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form:  a) Plant - On or about 04/17/14 and at times prior thereto employees cleaned (used) vacuum cleaner parts with compressed air, and wore surgical masks for protection. The employer did not assess the concentration and nature of the air contaminants to establish whether a respiratory protection program was needed to protect the workers.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View AMERICA'S REMANUFACTURING CO.'s full OSHA safety record →

EDIC

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339688525.