Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BANES ROOFING, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of BANES ROOFING, INC. in 1001 STERIGERE STREET, NORRISTOWN, PA 19401 (NAICS 238160). OSHA activity number 339694309.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Banes Roofing, INC. — free Get an email when a new federal OSHA severe-injury report for Banes Roofing, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
BANES ROOFING, INC.
Site address
1001 STERIGERE STREET
City
NORRISTOWN
State
PA
ZIP
19401
Mailing
80 S. 3RD STREET, TELFORD, PA 18969
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
8
Ownership type
A

4 citations on file for this inspection.

1926.502 F02 IV

Serious Gravity 5 1 instance 8 exposed
Issued
Sep 9, 2014
Penalty
Initial $2,200 · Current $1,540 Reduced
29 CFR 1926.502(f)(2)(iv): The rope, wire, or chain shall have a minimum tensile strength of 500 pounds (2.22 kN), and after being attached to the stanchions, shall be capable of supporting, without breaking, the loads applied to the stanchions as prescribed in paragraph (f)(2)(iii) of this section; and  a)1001 Sterigere Street, Roof - on or about April 17, 2014, employees were working on a low slope roof with an installed warning line system including a warning line consisting of caution tape, which did not have a minimum tensile strength of 500 pounds.
Recent events (2)
  • — I (S) $1540
  • — Z (S) $2200

1926.502 F02 I

Serious Gravity 5 1 instance 8 exposed
Issued
Sep 9, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.502(f)(2)(i): The rope, wire, or chain shall be flagged at not more than 6-foot (1.8 m) intervals with high-visibility material;  a)1001 Sterigere Street, Roof - on or about April 17, 2014, employees were working on a roof with an installed warning line which was not flagged at a six foot maximum interval with a high-visibility material.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B10

Repeat Gravity 10 1 instance 8 exposed
Issued
Sep 9, 2014
Abate by
Sep 19, 2014
Penalty
Initial $15,400 · Current $10,780 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.    a) 1001 Sterigere Street, Roof - on or about April 17, 2014, employees conducting roofing work on a low slope roof, approximately 42 feet above grade, were not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a warning line system.   Banes Roofing, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(10), which was contained in OSHA inspection number 314226283, citation number 1, item number 1(a) and was affirmed as a final order on April 15, 2010, with respect to a workplace located at 930 Washington Avenue, Philadelphia, PA.
Recent events (2)
  • — I (R) $10780
  • — Z (R) $15400

1926.503 B01

Other-than-serious 1 instance 8 exposed
Issued
Sep 9, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer.  a) 1001 Sterigere Street, Roof - on or about April 17, 2014, the employer acknowledged conducting training for employees which require the use of fall protection methods, but did not verify compliance with paragraph (a) of this section by preparing a written training certification record, including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Banes Roofing, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339694309.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.