Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,195,903Inspections Most recent open 2026-08-18 Last loaded 2026-08-21

OSHA Inspection: AIRLITE PLASTICS COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AIRLITE PLASTICS COMPANY in 6110 ABBOTT DR., OMAHA, NE 68110 (NAICS 326199). OSHA activity number 339694507.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Airlite Plastics Company for free Get an email when a new federal OSHA severe-injury report for Airlite Plastics Company is published. One employer, no account, unsubscribe in one click.
Site address
6110 ABBOTT DR.
City
OMAHA
State
NE
ZIP
68110
Mailing
PO BOX 8400, OMAHA, NE 68108
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
816
Ownership type
Private (A)

2 citations on file for this inspection.

1910.305 B01 II

Serious Gravity 5 1 instance 6 exposed
Issued
Jul 30, 2014
Abate by
Aug 11, 2014
Penalty
Initial $4,250 · Current $4,250
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:   The employer is failing to ensure that employees are protected from electrical hazards.  Employees working near or on the electrical outlet on the HD regrind line in this area are exposed to live parts due missing "knock-out plugs" creating openings in this box.
Recent events (2)
  • · I (S) $4250
  • · Z (S) $4250

1910.305 G01 IV A

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Jul 30, 2014
Penalty
Initial $4,250 · Current $0 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  The employer is failing to ensure employees are protected from electrical hazards.  These include, but are not limited to the following.  Extension cords are being attached to the building surface and run over a walkway to power the employees microwave oven.
Recent events (2)
  • · I (S) $0
  • · Z (S) $4250

View Airlite Plastics Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339694507.