PAXINOS, PA ·
OSHA Inspection: NATIONAL TICKET CO.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NATIONAL TICKET CO. in 5562 SNYDERTOWN ROAD, PAXINOS, PA 17860 (NAICS 323111). OSHA activity number 339742025.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NATIONAL TICKET CO.
- Site address
- 5562 SNYDERTOWN ROAD
- City
- PAXINOS
- State
- PA
- ZIP
- 17860
- Mailing
- P.O. BOX 547, SHAMOKIN, PA 17872
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323111
- Employees
- 135
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.212 A01
- Issued
- Sep 17, 2014
- Penalty
- Initial $3,600 · Current $2,700 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Press Area: The zigzag folder Z-201 on the JRD press #R17 was not guarded to protect the operator from the point of operation, exposing employees to potential injuries on or about April 24, 2014. Abatement Observed During Inspection. No certification or documentation required.
Recent events (2)
- · I (S) $2700
- · Z (S) $3600
1910.305 B01 II
- Issued
- Sep 17, 2014
- Abate by
- Sep 29, 2014
- Penalty
- Initial $1,951 · Current $1,463 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) JRD Press Area: On the JRD-5 press #R17, a knockout in the handy box was not closed, thereby exposing employees to electrical hazards, as observed on or about April 24, 2014. Abatement Certification Required.
Recent events (2)
- · I (S) $1463.25
- · Z (S) $1951
1910.22 A01
- Issued
- Sep 17, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition. a) At 5562 Snydertown Road, Paxinos, PA 17860, in the Warehouse: The maintenance storage area was not kept clean and orderly, exposing employees to slips/trips/falls on or about April 24, 2014. ABATEMENT OBSERVED DURING INSPECTION. NO CERTIFICATION REQUIRED.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.303 B02
- Issued
- Sep 17, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) At 5562 Snydertown Road, Paxinos, PA 17860, in the Lunch Room: Employees used a power strip (relocatable power tap--RPT) to provide electrical power to a microwave oven. Employees were exposed to electrical hazards on or about April 24, 2014. ABATEMENT OBSERVED DURING INSPECTION. NO CERTIFICATION REQUIRED.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.303 G01
- Issued
- Sep 17, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) Maintenance Shop: Sufficient access and working space was not provided and maintained to the surface grinder's main disconnect 240 volts panel and materials were stored in front of the electrical panes prohibiting immediate access thereby exposing employees to electrical hazards, as observed on or about April 24, 2014. ABATEMENT OBSERVED DURING INSPECTION. NO CERTIFICATION REQUIRED.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at National Ticket CO.
View National Ticket CO.'s full OSHA safety record →
More inspections in this industry (NAICS 323111)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339742025.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.