Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: INFINITY CONSTRUCTION SERVICES

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of INFINITY CONSTRUCTION SERVICES in 622 COMMERCE, CLUTE, TX 77531 (NAICS 332996). OSHA activity number 339742926.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Infinity Construction Services — free Get an email when a new federal OSHA severe-injury report for Infinity Construction Services is published. One employer, no account, unsubscribe in one click.
Site address
622 COMMERCE
City
CLUTE
State
TX
ZIP
77531
Mailing
622 COMMERCE, CLUTE, TX 77531
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332996
Employees
110
Ownership type
A

2 citations on file for this inspection.

1910.252 B02 III

Other-than-serious 2 instances 68 exposed
Issued
Jul 29, 2014
Abate by
Aug 14, 2014
Penalty
Initial $4,000 · Current $4,000
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields:    a)  North stainless steel pipe fitting Welding Shop - Employees working and walking were exposed to ultraviolet light when not protected by a noncombustible or flameproof screen or shield when welders were welding and fabricating pipes.    b)  South carbon steel pipe fitting Welding Shop - Employees working and walking were exposed to ultraviolet light when not protected by a noncombustible or flameproof screen or shield when welders were welding and fabricating pipes.
Recent events (3)
  • — R (O) $4000
  • — C (S) $4000
  • — Z (S) $4000

1910.134 C01 V

Deleted Other-than-serious 1 instance 2 exposed
Issued
Jul 29, 2014
Abate by
Aug 4, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(1)(v): The written program did not contain procedures and schedules for cleaning, disinfecting, storing, inspecting, repairing, discarding, and otherwise maintaining respirators:  a)   At the facility, the respiratory protection program did not contain procedures to clean, disinfect and store the 88 VX Series Airline respirator located in the sand blasting outdoor warehouse located on the east side of the plant.
Recent events (3)
  • — R (O) $0
  • — C (O) $0
  • — Z (O) $0

View Infinity Construction Services's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339742926.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.