Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: GENESEE GLOBAL GROUP

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GENESEE GLOBAL GROUP in 975 JOHN STREET, WEST HENRIETTA, NY 14586 (NAICS 333513). OSHA activity number 339744278.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Genesee Global Group for free Get an email when a new federal OSHA severe-injury report for Genesee Global Group is published. One employer, no account, unsubscribe in one click.
Site address
975 JOHN STREET
City
WEST HENRIETTA
State
NY
ZIP
14586
Mailing
975 JOHN STREET, WEST HENRIETTA, NY 14586
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333513
Employees
48
Ownership type
Private (A)

3 citations on file for this inspection.

1910.217 B07 XV

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
May 6, 2014
Abate by
May 27, 2014
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.217(b)(7)(xv): Selection of bar operation shall be by means capable of being supervised by the employer:  a) On or about 04/25/14 in the power press department; employer failed to maintain the bar function on press #26 by using a single air valve instead of a dual air valve exposing employees to contact with electric current.     Abatement Certification Required
Recent events (2)
  • · I (S) $0
  • · Z (S) $2800

1910.217 E02

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
May 6, 2014
Abate by
May 27, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.217(e)(2): Instructions to establish new or changed guidelines for use and care of mechanical power press were not furnished when mechanical power press were modified:   a) On or about 04/24/14 in the press department; employer failed to establish instructions for the use of power press #26 when a  single air valve was installed instead of a dual air valve exposing employees to contact with electric current.     Abatement Certification Required
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.333 C02

Serious Gravity 5 1 instance 3 exposed
Issued
May 6, 2014
Abate by
May 27, 2014
Penalty
Initial $4,200 · Current $2,520 Reduced
29 CFR 1910.333(c)(2): The employer did not ensure that only qualified persons were working on energized circuits and that qualified persons were familiar with the proper use of special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools;     a) On or about 04/25/14 in the Press Area; employer exposed employees to contact with electrical current ( 120 volts AC ) when they allowed access to the control circuits of Press # 26.   Unqualified employees would access the electrical panel of Press #26 and using two strips of metal reset control circuits 7 and 8 while energized.       Abatement Certification Required
Recent events (2)
  • · I (S) $2520
  • · Z (S) $4200

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339744278.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.