COCOA, FL —
OSHA Inspection: BARRON'S WHOLESALE TIRE, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BARRON'S WHOLESALE TIRE, LLC in 101 ST. JOHNS AVE., COCOA, FL 32922 (NAICS 493110). OSHA activity number 339745028.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BARRON'S WHOLESALE TIRE, LLC
- Site address
- 101 ST. JOHNS AVE.
- City
- COCOA
- State
- FL
- ZIP
- 32922
- Mailing
- 101 ST. JOHNS AVE., COCOA, FL 32922
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- Employees
- 250
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.36 G02
- Issued
- May 20, 2014
- Abate by
- Jul 8, 2014
- Penalty
- Initial $2,700 · Current $1,620 Reduced
General-duty citation text
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points: a. Warehouse - during warehouse operations where tires were stored, exit access was less than 28 inches, in that, stored tires took up additional space in the aisle ways and created the exit access less than 28 inches. Violation observed on or about 4/24/14.
Recent events (2)
- — I (S) $1620
- — Z (S) $2700
1910.178 G02
- Issued
- May 20, 2014
- Abate by
- Jul 8, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(g)(2): Battery changing and charging installations for industrial trucks were not provided for flushing and neutralizing spilled electrolyte, for fire protection, for protecting charging apparatus from damage from trucks, and for adequate ventilation for dispersal of fumes from batteries: a. Battery charging area - battery charging stations did not have water hoses for flushing spilled electrolyte. Violation observed on or about 4/24/14.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 L06
- Issued
- May 20, 2014
- Abate by
- Jul 8, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): The certification did not include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation: a. Warehouse - the employer did not have certification documentation when employees used Crown SP 3000 forklift and Raymond 261-OPC30TT forklift during warehouse operations. Violation observed on or about 4/24/14.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 493110)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339745028.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.