OSHA Inspection: VIOLI'S INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of VIOLI'S INC. in 209 CENTER STREET, MASSENA, NY 13662 (NAICS 722110). OSHA activity number 339746638.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Violi'S INC. for free Get an email when a new federal OSHA severe-injury report for Violi'S INC. is published. One employer, no account, unsubscribe in one click.
Establishment
VIOLI'S INC.
Site address
209 CENTER STREET
City
MASSENA
State
NY
ZIP
13662
Mailing
P.O. BOX 446, MASSENA, NY 13662
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
722110
Employees
9
Ownership type
Private (A)

2 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 21, 2014
Abate by
Sep 10, 2014
Penalty
Initial $2,800 · Current $1,950 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    a)  At the establishment, on or about 4/24/14:  The employer had not established a lockout/tagout program, including energy control procedures, employee training and periodic inspections to ensure that before any employee performed servicing or maintenance on equipment, including, but not limited to LaParmigiana pasta machine, Model D65 DV, meat slicer, mixer, that the machine or equipment was isolated from the energy source and rendered inoperative.    Abatement documentation must be submitted for this item.
Recent events (3)
  • · C (S) $2800
  • · J (S) $1950
  • · Z (S) $2800

1910.212 A01

Serious Gravity 10 2 instances 1 exposed
Issued
Aug 21, 2014
Abate by
Sep 10, 2014
Penalty
Initial $2,800 · Current $1,950 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a)  Basement, on or about 4/24/14:  Rotating parts and ingoing nip points on a LaParmigiana pasta machine, Model D65 DV were not guarded on the mixing hopper and the extruding hopper.    Abatement documentation must be submitted for this item.
Recent events (3)
  • · C (S) $2800
  • · J (S) $1950
  • · Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339746638.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.