OSHA Inspection: WONTON FOOD CORPORATION

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of WONTON FOOD CORPORATION in 2902 CAROLINE STREET, HOUSTON, TX 77004 (NAICS 311999). OSHA activity number 339748212.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wonton Food Corporation — free Get an email when a new federal OSHA severe-injury report for Wonton Food Corporation is published. One employer, no account, unsubscribe in one click.
Site address
2902 CAROLINE STREET
City
HOUSTON
State
TX
ZIP
77004
Mailing
2902 CAROLINE STREET, HOUSTON, TX 77004
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
Yes
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311999
Employees
72
Ownership type
A

5 citations on file for this inspection.

1910.29 A03 VII

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 22, 2014
Abate by
Sep 30, 2014
Penalty
Initial $4,900 · Current $3,920 Reduced
29 CFR 1910.29(a)(3)(vii): Work levels 10 feet or higher above the ground or floor did not have a guardrail of 2" x 4" nominal or the equivalent, installed no less than 36" or more than 42" high, with a mid-rail of 1"x 4" nominal lumber or equivalent:    a)  At the worksite where the guardrail on the working level of a mobile work platform, approximately 17 feet above the ground level, was less than 36 inches high.
Recent events (2)
  • — I (S) $3920
  • — Z (S) $4900

1910.147 C04

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 22, 2014
Abate by
Oct 5, 2014
Penalty
Initial $7,000 · Current $5,600 Reduced
29 CFR 1910.147(c)(4):  Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in the activities covered by this section:      a)  In the Noodle Building, on or about April 27, 2014, where energy control procedures had not been developed and utilized for the Beijing noodle machine when employees performed servicing and maintenance activities such as, but not limited to, cleaning the dough hooks and tubs when switching colors and at the end of the work shifts.  This exposed employees to caught-in and struck-by hazards.
Recent events (2)
  • — I (S) $5600
  • — Z (S) $7000

1910.157 G01

Serious Gravity 1 1 instance 3 exposed
Issued
Sep 22, 2014
Abate by
Sep 30, 2014
Penalty
Initial $2,100 · Current $1,680 Reduced
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting:      a) At the worksite where an educational program was not provided to employees and an emergency action plan had not been developed.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2100

1910.212 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 22, 2014
Abate by
Oct 5, 2014
Penalty
Initial $7,000 · Current $5,600 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:      a)  In the noodle room, where the tub on the Beijing noodle machine was not guarded to prevent contact with rotating parts.
Recent events (2)
  • — I (S) $5600
  • — Z (S) $7000

1910.305 G01 IV A

Other-than-serious 1 instance 3 exposed
Issued
Sep 22, 2014
Penalty
Initial $700 · Current $560 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    a) At the worksite where a commercial bug light, attached to the building, was connected by a flexible cord.