LINCOLNSHIRE, IL —
OSHA Inspection: STAR CREATIONS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of STAR CREATIONS, INC. in 610 SCHELTER ROAD, LINCOLNSHIRE, IL 60069 (NAICS 339999). OSHA activity number 339748972.
Where did this inspection happen?
- Establishment
- STAR CREATIONS, INC.
- Site address
- 610 SCHELTER ROAD
- City
- LINCOLNSHIRE
- State
- IL
- ZIP
- 60069
- Mailing
- 610 SCHELTER ROAD, LINCOLNSHIRE, IL 60069
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339999
- Employees
- 206
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.178 L01 I
- Issued
- Abate by
- Penalty
- Initial $6300.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) Facility Wide- The employer failed to ensure that each powered industrial truck operator was competent to operate powered industrial trucks, such as the Yale Forklift, Serial #B295N01671L, Hyster Forklift, Serial #188939, and the Crown Motorized Pallet Jack, Serial #6A191613, safely as demonstrated by the successful completion of the training and evaluation. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $3000
- — Z (S) $6300
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $5400.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Assembly Area- The employer failed to ensure that all areas where hazards were created by the point of operation, rotating parts and pinch points, were guarded on machinery such as the Coda Laminators at Stations 1, 2, 3, 4, 5, and 6, to prevent injury to employees during operation. b) The employer failed to ensure that all areas where hazards were created by the point of operation, rotating parts and pinch points, were guarded on machinery such as the Rotdevin Gluers at Stations 1, 2, 3, 4, 5, and 6, to prevent injury to employees during operation. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $3000
- — Z (S) $5400
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $5400.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Assembly Area- The employer failed to ensure that electrical equipment, such as the multiple outlet relocatable power taps in the Assembly Area, was being used only to power audiovisual equipment as permitted under its listing and labeling. The multiple outlet relocatable power taps were found be being used to power additional multiple outlet relocatable power taps, U-Line Glue Guns and other extension cords. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $3000
- — Z (S) $5400
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $2700.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Assembly Area- The employer failed to provide permanent wiring where needed, such as running to the Assembly Tables to power the U-Line Glue Guns, and flexible cords were used as a substitute. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $2700
1904.29 A
- Issued
- Penalty
- Initial $765.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1904.29(a): The employer did not use an OSHA 300, 301 and 300A Form or equivalent. a) Facility Wide- The employer failed to log any injuries to workers for 2014 on an OSHA 300 Log or comparable form. Also, a Summary of Work-Related Injuries and Illnesses form (OSHA 300A) or equivalent form was not completed for the year 2013. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $765
More inspections in this industry (NAICS 339999)
CELINA, TN—2026-07-08
TIGRE USA INC.
ROCHESTER HILLS, MI—2026-06-30
ARAYMOND USA DBA ARAYMOND FLUID HANDLING NORTH AMERICA INC
KINGS MOUNTAIN, NC—2026-06-26
161439 - BUCKEYE FIRE EQUIPMENT COMPANY
SUFFIELD, CT—2026-06-25
RUG PAD USA LLC
MINNEAPOLIS, MN—2026-06-25
111490 - FIFIELD COMPANIES INC DBA POWDER COATING TECHNOLOG
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339748972.