Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: MACHINE DYNAMICS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MACHINE DYNAMICS, INC. in 303 SOUTH STATE, PRESTON, ID 83263 (NAICS 333220). OSHA activity number 339750994.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Machine Dynamics, INC. for free Get an email when a new federal OSHA severe-injury report for Machine Dynamics, INC. is published. One employer, no account, unsubscribe in one click.
Site address
303 SOUTH STATE
City
PRESTON
State
ID
ZIP
83263
Mailing
POB 332, PRESTON, ID 83263
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333220
Employees
2
Ownership type
Private (A)

3 citations on file for this inspection.

1910.147 C04 I

Other-than-serious 4 instances 1 exposed
Issued
May 20, 2014
Abate by
Jun 16, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section.  (a)    CNC Mazak VTC 200B, serial 145511 (mill)   (b)    CNC Mazak Nexus 510C, serial 172324 (mill)  (c)    Mazatrol PC-Fusion CNC 640 (lathe)   (d)    MAZAK "Quick turn" Nexus 250.  Note: Abatement certification IS required for this item.
Recent events (1)
  • · Z (O) $0

1910.178 L06

Other-than-serious 1 instance 1 exposed
Issued
May 20, 2014
Abate by
Jun 16, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):   a)      There was no record/certification of training for the powered industrial truck operator.    Note: Abatement certification IS required for this item.
Recent events (1)
  • · Z (O) $0

1910.212 A03 IV E

Other-than-serious 2 instances 1 exposed
Issued
May 20, 2014
Abate by
Jun 16, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(3)(iv)(e): Employee(s) were using milling machines without point of operation guarding in place.  (a)  Interlock disconnected on the CNC Mazak VTC 200B, serial 145511 (mill).  (b)  Interlock disconnected on the CNC Mazak Nexus 510C, serial 172324 (mill).  Note: Abatement certification IS required for this item.