PRESTON, ID ·
OSHA Inspection: MACHINE DYNAMICS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MACHINE DYNAMICS, INC. in 303 SOUTH STATE, PRESTON, ID 83263 (NAICS 333220). OSHA activity number 339750994.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MACHINE DYNAMICS, INC.
- Site address
- 303 SOUTH STATE
- City
- PRESTON
- State
- ID
- ZIP
- 83263
- Mailing
- POB 332, PRESTON, ID 83263
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333220
- Employees
- 2
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- May 20, 2014
- Abate by
- Jun 16, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section. (a) CNC Mazak VTC 200B, serial 145511 (mill) (b) CNC Mazak Nexus 510C, serial 172324 (mill) (c) Mazatrol PC-Fusion CNC 640 (lathe) (d) MAZAK "Quick turn" Nexus 250. Note: Abatement certification IS required for this item.
Recent events (1)
- · Z (O) $0
1910.178 L06
- Issued
- May 20, 2014
- Abate by
- Jun 16, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): a) There was no record/certification of training for the powered industrial truck operator. Note: Abatement certification IS required for this item.
Recent events (1)
- · Z (O) $0
1910.212 A03 IV E
- Issued
- May 20, 2014
- Abate by
- Jun 16, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(3)(iv)(e): Employee(s) were using milling machines without point of operation guarding in place. (a) Interlock disconnected on the CNC Mazak VTC 200B, serial 145511 (mill). (b) Interlock disconnected on the CNC Mazak Nexus 510C, serial 172324 (mill). Note: Abatement certification IS required for this item.
Recent events (1)
- · Z (O) $0
More inspections at Machine Dynamics, INC.
View Machine Dynamics, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333220)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339750994.