5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JACK'S ROOFING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JACK'S ROOFING in 2367 KING PL, WASHINGTON, DC 20016 (NAICS 238160). OSHA activity number 339753659.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Jack'S Roofing — free Get an email when a new federal OSHA severe-injury report for Jack'S Roofing is published. One employer, no account, unsubscribe in one click.
Establishment
JACK'S ROOFING
Site address
2367 KING PL
City
WASHINGTON
State
DC
ZIP
20016
Mailing
2345 MONTGOMERY ST, SILVER SPRING, MD 20910
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
20
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 2 instances 2 exposed
Issued
Jul 1, 2014
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501      a) On April 16, 2014 and at times prior thereto; roof area; employees were observed working on a residential roof without a personal fall arrest system to prevent them from falling 25-30 feet to ground level; roof pitch 4:12.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 1, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:     a) On April 16, 2014 and at times prior thereto; Northside of residential home; the ladder used to access the work area (roof) was 18 inches above the working platform exposing them to a fall hazard of 22 feet to ground level while reaching for the of the ladder.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

View Jack'S Roofing's full OSHA safety record →