WASHINGTON, DC —
OSHA Inspection: JACK'S ROOFING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JACK'S ROOFING in 2367 KING PL, WASHINGTON, DC 20016 (NAICS 238160). OSHA activity number 339753659.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JACK'S ROOFING
- Site address
- 2367 KING PL
- City
- WASHINGTON
- State
- DC
- ZIP
- 20016
- Mailing
- 2345 MONTGOMERY ST, SILVER SPRING, MD 20910
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 20
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Jul 1, 2014
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 a) On April 16, 2014 and at times prior thereto; roof area; employees were observed working on a residential roof without a personal fall arrest system to prevent them from falling 25-30 feet to ground level; roof pitch 4:12.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1926.1053 B01
- Issued
- Jul 1, 2014
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On April 16, 2014 and at times prior thereto; Northside of residential home; the ladder used to access the work area (roof) was 18 inches above the working platform exposing them to a fall hazard of 22 feet to ground level while reaching for the of the ladder.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
More inspections at Jack'S Roofing