Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,192,068Inspections Most recent open 2026-08-04 Last loaded 2026-08-07

OSHA Inspection: LINK FORD AND RV

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of LINK FORD AND RV in 2700 DECKER DRIVE, RICE LAKE, WI 54868 (NAICS 441310). OSHA activity number 339754780.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Link Ford and RV for free Get an email when a new federal OSHA severe-injury report for Link Ford and RV is published. One employer, no account, unsubscribe in one click.
Establishment
LINK FORD AND RV
Site address
2700 DECKER DRIVE
City
RICE LAKE
State
WI
ZIP
54868
Mailing
2700 DECKER DRIVE, RICE LAKE, WI 54868
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441310
Employees
50
Ownership type
A

6 citations on file for this inspection.

1910.215 A04

Serious Gravity 5 1 instance 6 exposed
Issued
Jul 21, 2014
Abate by
Aug 18, 2014
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery was not adjusted closely to the wheel with a maximum opening of one eighth inch:    (a) Service Department, east wall work bench area; The work rest on the Delta 1/2 HP bench grinder was set at approximately 5/8 inch from the abrasive wheel.
Recent events (2)
  • · I (S) $1750
  • · Z (S) $3500

1910.215 B09

Serious Gravity 5 1 instance 6 exposed
Issued
Jul 21, 2014
Abate by
Aug 18, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  (a) Service Department, east wall work bench area; The tongue guard on the Delta 1/2 HP bench grinder was adjusted above the periphery guard with and opening that measured approximately 7/8 inch from the abrasive wheel.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.242 B

Serious Gravity 1 1 instance 4 exposed
Issued
Jul 21, 2014
Abate by
Aug 18, 2014
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    (a) Throughout the Service Department; Compressed air nozzles were not ported to reduce the air pressure and produced an air pressure that measured approximately 110 p.s.i.
Recent events (2)
  • · I (S) $1050
  • · Z (S) $2100

1910.1200 E01 I

Serious Gravity 5 1 instance 10 exposed
Issued
Jul 21, 2014
Abate by
Aug 18, 2014
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.1200(e)(1)(i): The written hazard communication program did not include a list of the hazardous chemicals known to be present, using an identity that was referenced on the appropriate material safety data sheet:    (a) Service Department; The employer did not develop and maintain a list of the hazardous chemicals known to be present, such as, but not limited to, BG Diesel ISC, BG DOC Diesel Oil Conditioner, BG EPR Engine Performance Restoration, BG Fuel Injection Cleaner and BG Air Intake Systems Cleaner.
Recent events (2)
  • · I (S) $1750
  • · Z (S) $3500

1910.1200 G01

Serious Gravity 5 1 instance 10 exposed
Issued
Jul 21, 2014
Abate by
Aug 18, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use:  (a) Service Department; The employer did not retain and make available material safety data sheets (MSDSs) for hazardous chemicals used by service technicians, such as, but not limited to, BG Diesel ISC, BG DOC Diesel Oil Conditioner, BG EPR Engine Performance Restoration, BG Fuel Injection Cleaner and BG Air Intake Systems Cleaner.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.1200 H01

Serious Gravity 5 1 instance 10 exposed
Issued
Jul 21, 2014
Abate by
Aug 18, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  (a) Service Department; The employer did not provide service technicians effective training in the use of hazardous chemicals in the work place, such as, but not limited to, BG Diesel ISC, BG DOC Diesel Oil Conditioner, BG EPR Engine Performance Restoration, BG Fuel Injection Cleaner and BG Air Intake Systems Cleaner.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339754780.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.