OSHA Inspection: GERBER PAYROLL SERVICES INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of GERBER PAYROLL SERVICES INC. in 8030 WILLIAM PENN HIGHWAY, EASTON, PA 18045 (NAICS 811121). OSHA activity number 339755191.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gerber Payroll Services INC. — free Get an email when a new federal OSHA severe-injury report for Gerber Payroll Services INC. is published. One employer, no account, unsubscribe in one click.
Site address
8030 WILLIAM PENN HIGHWAY
City
EASTON
State
PA
ZIP
18045
Mailing
8030 WILLIAM PENN HIGHWAY, EASTON, PA 18045
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811121
Employees
12
Ownership type
A

5 citations on file for this inspection.

1910.107 B05 I

Serious Gravity 1 1 instance 2 exposed
Issued
Jul 25, 2014
Abate by
Aug 29, 2014
Penalty
Initial $3,300 · Current $2,475 Reduced

Hazardous substances 2590

29 CFR 1910.107(b)(5)(i): Spraying operation(s) (except electrostatic spraying operations) were not designed, installed and maintained such that the average air velocity over the open face of the booth (or booth cross section during spraying operations) was not less than 100 linear feet per minute and visible gauges or audible alarm or pressure activated devices were not installed to indicate or insure that the required air velocity was maintained:  a. Small Spray Booth - On or about May 5, 2014, employees were spray painting with flammable paints (Class 1C or Category 3) where the ventilation for the dry filtered booth was recorded at an average of 55 fpm and the spray booth did not have visible gauges or an audible alarm to inform employees that the minimum air flow level was not being maintained.
Recent events (2)
  • — I (S) $2475
  • — Z (S) $3300

1910.107 C07

Serious Gravity 5 3 instances 2 exposed
Issued
Jul 25, 2014
Abate by
Aug 29, 2014
Penalty
Initial $5,500 · Current $4,125 Reduced

Hazardous substances 2590

29 CFR 1910.107(c)(7): Electric lamps outside of but within 20 feet of spraying area(s), were not separated by partition(s), or totally enclosed to prevent the falling of hot particles and protected from mechanical injury by suitable guards or by location:  a. Small Spray Booth - On or about May 5, 2014, employees were exposed to the hazards of burns from fires caused by  sparks and hot particles falling within the spraying area from lights that are not enclosed or separated by a partition.
Recent events (2)
  • — I (S) $4125
  • — Z (S) $5500

1910.107 G01

Serious Gravity 1 2 instances 1 exposed
Issued
Jul 25, 2014
Abate by
Aug 29, 2014
Penalty
Initial $0 · Current $0

Hazardous substances 108016752590

29 CFR 1910.107(g)(1): Spraying was conducted outside of predetermined spraying areas:  A. Small Spray booth -  On or about May 28, 2014, An employee, was spraying a solvent based primer (Category 2) outside of the predetermined spraying as the car being painted did not totally fit within the spray paint booth during the painting operation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 B10

Serious Gravity 1 1 instance 2 exposed
Issued
Jul 25, 2014
Abate by
Aug 29, 2014
Penalty
Initial $3,300 · Current $2,475 Reduced

Hazardous substances 2590

29 CFR 1910.107(b)(10): 29 CFR 1910.107(b)(10):  Illumination panels did not effectively isolate the spraying area from the area in which the lighting unit is located.   a. Small Spray Booth - On or about May 2, 2014, a ceiling lighting fixture panel was cracked in multiple areas and was missing glass in one corner which permitted exposure of the fixture components paint vapors.  Exposing employees to fire and burn hazards.
Recent events (2)
  • — I (S) $2475
  • — Z (S) $3300

1910.141 D02 II

Serious Gravity 1 1 instance 12 exposed
Issued
Jul 25, 2014
Abate by
Aug 29, 2014
Penalty
Initial $3,300 · Current $2,475 Reduced
29 CFR 1910.141(d)(2)(ii): Lavatories were not provided with hot and cold, or tepid running water:  a. Establishment - On or about May 2, 2014, employees conducting autobody work to include sanding and spray painting are exposed to various chemicals and the employer did not provide heated water in each lavatory for the purposes of cleansing.
Recent events (2)
  • — I (S) $2475
  • — Z (S) $3300

View Gerber Payroll Services INC.'s full OSHA safety record →