Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PIRHL, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PIRHL, LLC in 12220 YMCA DRIVE, EDINBORO, PA 16412 (NAICS 236116). OSHA activity number 339755548.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pirhl, LLC — free Get an email when a new federal OSHA severe-injury report for Pirhl, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
PIRHL, LLC
Site address
12220 YMCA DRIVE
City
EDINBORO
State
PA
ZIP
16412
Mailing
4949 GALAXY PARKWAY SUITE S, WARRENSVILLE HEIGHTS, OH 44128
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
1
Ownership type
A

5 citations on file for this inspection.

1926.153 L

Serious Gravity 1 1 instance 3 exposed
Issued
Jun 12, 2014
Abate by
Jul 9, 2014
Penalty
Initial $1,607 · Current $1,205 Reduced
29 CFR 1926.153(l): LP-Gas storage locations were not provided with at least one approved portable fire extinguisher having a rating of not less than 20B:C:    A.)  PIRHL, LLC, 12220 YMCA Drive, Edinboro, PA  16412, east side of the structure, on or about May 5, 2014 and times prior thereto:  A 120 gallon propane cylinder was stored outside on the east side of the building.  The closest fire extinguisher was located 109 feet from the propane cylinder in the construction office trailer.
Recent events (2)
  • — I (S) $1205.25
  • — Z (S) $1607

1910.1200 F05 I

Serious Gravity 1 1 instance 3 exposed
Issued
Jun 12, 2014
Abate by
Jul 9, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: (Construction Reference: 1926.59)  A.) PIRHL, LLC, 12220 YMCA Drive, Edinboro, PA  16412, east side of the structure, on or about May 5, 2014 and times prior thereto:  A 120 gallon propane cylinder was stored outside on the east side of the building.  The cylinder was not clearly labeled to identify its contents as propane.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 F05 II

Serious Gravity 1 1 instance 3 exposed
Issued
Jun 12, 2014
Abate by
Jul 9, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings: (Construction Reference: 1926.59)  A.) PIRHL, LLC, 12220 YMCA Drive, Edinboro, PA  16412, east side of the structure, on or about May 5, 2014 and times prior thereto:  A 120 gallon propane cylinder was stored outside on the east side of the building.  The cylinder was not clearly labeled to identify the hazards of propane.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.151 A03

Serious Gravity 1 1 instance 3 exposed
Issued
Jun 12, 2014
Abate by
Jul 9, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.151(a)(3): The vicinity of operations which constituted a fire hazard were not conspicuously posted: No Smoking Or Open Flame:  A.) PIRHL, LLC, 12220 YMCA Drive, Edinboro, PA  16412, east side of the structure, on or about May 5, 2014 and times prior thereto:  A 120 gallon propane cylinder was stored outside on the east side of the building.  A no smoking and/or no open flame sign was not posted at the tank and/or in the vicinity of the tank.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.150 C01 VIII

Other-than-serious 1 instance 3 exposed
Issued
Jun 12, 2014
Abate by
Jul 9, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.150(c)(1)(viii): Portable fire extinguishers were not inspected periodically and maintained in accordance with maintenance and use of portable fire extinguishers, N.F.P.A. No. 10A-1970:  A.) PIRHL, LLC, 12220 YMCA Drive, Edinboro, PA  16412, inside construction office trailer, on or about May 5, 2014 and times prior thereto:  The Kidde Multi-Purpose Dry Chemical Fire Extinguisher (S/N:  AF-084256) had its last annual maintenance in January 2013.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Pirhl, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339755548.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.