OSHA Inspection: ACCURATE BOX COMPANY, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ACCURATE BOX COMPANY, INC. in 86 FIFTH AVE., PATERSON, NJ 07524 (NAICS 322212). OSHA activity number 339755910.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Accurate BOX Company, INC. — free Get an email when a new federal OSHA severe-injury report for Accurate BOX Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
86 FIFTH AVE.
City
PATERSON
State
NJ
ZIP
07524
Mailing
86 FIFTH AVE., PATERSON, NJ 07524
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322212
Employees
200
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 5 exposed
Issued
Nov 3, 2014
Penalty
Initial $6,930 · Current $6,930
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    a)  Production Area Die Cutter #6: Employees were exposed to potentially hazardous energy while entering a die cutting machine without utilizing the specific procedures for locking and tagging out sources of energy, on or about 05/06/2014.
Recent events (3)
  • — J (S) $6930
  • — C (S) $6930
  • — Z (S) $6930

1910.147 C05 I

Serious Gravity 10 1 instance 5 exposed
Issued
Nov 3, 2014
Penalty
Initial $6,930 · Current $6,930
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources:    a)  Production Area Die Cutter #6: Employer did not provide locks, tags, wedges, key blocks, adapter pins, self locking fasteners, or other hardware to employees to properly isolate, secure, of blocking of machines or equipment from energy sources, on or about 05/06/2014.
Recent events (3)
  • — J (S) $6930
  • — C (S) $6930
  • — Z (S) $6930

1910.147 C06 I

Serious Gravity 10 1 instance 5 exposed
Issued
Nov 3, 2014
Penalty
Initial $6,930 · Current $6,930
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    a)  Production Area Die Cutter #6: Employer did not conduct a periodic inspection of the energy control procedures at least annually to ensure that procedures were being followed, on or about 5/06/2014.
Recent events (3)
  • — J (S) $6930
  • — C (S) $6930
  • — Z (S) $6930

1910.333 B02 II B

Serious Gravity 10 1 instance 5 exposed
Issued
Nov 3, 2014
Penalty
Initial $6,930 · Current $6,930
29 CFR 1910.333(b)(2)(ii)(B): Control circuit devices, such as push buttons, selector switches, and interlocks, were used as the sole means for deenergizing circuits and equipment:    a) Production Area, Die Cutter #6: Employees were exposed to amputation and crushing hazards from potentially hazardous energy while entering a die cutting machine that the key switch on the operator's station was the only means of deenergizing circuits and other sources of energy, on or about 05/06/2014.
Recent events (3)
  • — J (S) $6930
  • — C (S) $6930
  • — Z (S) $6930

1910.212 A01

Repeat Gravity 10 1 instance 4 exposed
Issued
Nov 3, 2014
Penalty
Initial $13,860 · Current $7,000 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a)  Die Cutter #6, 86 Fifth Avenue, Paterson, NJ: Machine Guarding was not provided to protect the operator and other employees from the hazards created by the moving elevator, conveyor, and other moving parts, on or about 05/06/2014.    Accurate Box Company, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.212(a)(1), which was contained in OSHA inspection number 312863152, citation number 01, item number 002 and was affirmed as a final order on 06/09/2010, and OSHA inspection number 312864903, citation number 01, item number 004 and was affirmed as a final order on 11/03/2010 with respect to a workplace located at 86 Fifth Avenue, Paterson, NJ.
Recent events (3)
  • — J (R) $7000
  • — C (R) $13860
  • — Z (R) $13860

View Accurate BOX Company, INC.'s full OSHA safety record →