SAINT LOUIS, MO —
OSHA Inspection: BROCK AUTO PARTS & SALES CO.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BROCK AUTO PARTS & SALES CO. in 1907 KIENLEN AVENUE, SAINT LOUIS, MO 63133 (NAICS 423930). OSHA activity number 339756223.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BROCK AUTO PARTS & SALES CO.
- Site address
- 1907 KIENLEN AVENUE
- City
- SAINT LOUIS
- State
- MO
- ZIP
- 63133
- Mailing
- 1907 KIENLEN AVENUE, SAINT LOUIS, MO 63133
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 30
- Ownership type
- A
Citations
33 citations on file for this inspection.
5(a)(1)
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $3,500 · Current $2,000 Reduced
General-duty citation text
OSH ACT of 1970 Section 5(a)(1): Section (5)(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employee(s) in that employee(s) were exposed to the hazard of being struck-by: Inside of Building #2 a.k.a. Transmission Building, employee(s) were exposed to a struck-by hazard due to a possible unplanned collapse of the following shelving units that were not anchored: a/ 2TR176. b/ 2TR115. c/ 2TR112. d/ Rack-G. e/ Rack-B. f/ 2TR74. g/ R32W. h/ 2TR42. Inside of the Tire Room, employee(s) were exposed to a struck-by hazard due to a possible unplanned collapse of two shelving units that were not anchored: One method of abatement to correct this apparent hazard is to anchor each shelving unit with a sufficient number of column base plates and anchor bolts as required by ANSI MH16.1-2012, paragraph 1.4.7. DISCLAIMER: a/ The employer is not limited to the abatement method(s) suggested by OSHA. b/ The employer is responsible for selecting and implementing an effective abatement method.
Recent events (3)
- — J (S) $2000
- — C (S) $3500
- — Z (S) $3500
1910.22 A01
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $3,500 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): Place(s) of employment were not kept clean and orderly, or in a sanitary condition: Large quantities of scrap metal and other materials were located in walking/working areas in the following locations: a/ The Stainless Steel Building. b/ Scale House Building.
Recent events (3)
- — J (S) $1800
- — C (S) $3500
- — Z (S) $3500
1910.22 A02
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(a)(2): The floor of every workroom was not maintained in a clean and, so far as possible, a dry condition: a/ Inside of the Scale House Building, the walkway between the CD Can Densor 2000 and the concrete block wall was covered with a large puddle of liquid.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.22 D01
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): In every building or other structure, or part thereof, used for mercantile, business, industrial, or storage purposes, the loads approved by the building official were not marked on plates of approved design which were supplied and securely affixed by the owner of the building, or his duly authorized agent, in a conspicuous place in each space to which they relate: a/ Inside of the Tire Room, the safe load limit for the storage loft above the Inventory Room was not determined or marked with an appropriate plate.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.23 D01 IV
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(d)(1)(iv): Flight(s) of stairs with four (4) or more risers, more than 44 inches wide but less than 88 inches wide, were not equipped with one standard handrail on each enclosed side and one standard stair railing on each open side: a/ At the Steel Building, west end, a concrete flight of stairs, five risers high, was not equipped with a standard stair rail along its open side. The width of each tread was approximately 49 inches.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.23 D01 V
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(d)(1)(v): Flight(s) of stairs with four (4) or more risers, 88 or more inches wide, were not equipped with one standard handrail on each enclosed side, one standard railing on each open side and one intermediate standard stair railing located approximately midway of the width: a/ The concrete flight of stairs, ten risers high, and leading to the front door of the Main Office from the side walk was not equipped with a standard railing along the south end or an intermediate standard railing approximately midway of the width. The width of the tread was approximately 120 inches.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.23 E01
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(e)(1): A standard railing did not consist of top rail, intermediate rail, and posts, and did not have a vertical height of 42 inches nominal from upper surface of top rail to floor, platform, runway, or ramp level: a/ At the Steel Building, west end, the guardrail was not equipped with an intermediate rail. The fall distance to the ground below was approximately 49 inches. b/ At the Tire Room, the stair railing belonging to a wooden flight of stairs, 14 risers high, was not equipped with an intermediate rail. c/ At the Tire Room, the guardrail belonging to the storage loft was not equipped with an intermediate rail. The fall distance to the concrete floor below was approximately ten feet.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.101 B
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $3,500 · Current $500 Reduced
General-duty citation text
29 CFR 1910.101(b): Compressed gas cylinder(s ) were not properly supported to prevent them from being knocked over as referenced by Section 3.4.4., Compressed Gas Association Pamphlet P-1-1965: a/ Inside of Building #5, a compressed gas cylinder was stored in an upright, unsupported manner. b/ Inside of the Scale House Building, a compressed gas cylinder was stored in an upright, unsupported manner. c/ Inside of Building #2, three compressed gas cylinders were stored in an upright, unsupported manner.
Recent events (3)
- — J (O) $500
- — C (S) $3500
- — Z (S) $3500
1910.253 B03 II
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well protected, well ventilated, dry location, at least 20 feet from highly combustible materials such as oil or excelsior: a/ Inside of Building #5, one oxygen cylinder and another of acetylene were co-stored together.
Recent events (3)
- — J (O) $0
- — C (S) $0
- — Z (S) $0
1910.253 B02 IV
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use: a/ Inside of Building #5, an oxygen and acetylene compressed gas cylinder were co-stored together in an unsupported manner without their valve caps in place. b/ Inside of the Scale House Building, a single compressed gas cylinder was stored without its valve cap in place.
Recent events (3)
- — J (O) $0
- — C (S) $0
- — Z (S) $0
1910.132 D02
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $3,500 · Current $1,600 Reduced
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment: a/ The workplace hazard assessment was not certified.
Recent events (3)
- — J (S) $1600
- — C (S) $3500
- — Z (S) $3500
1910.133 A01
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a/ Inside of the Scale House Building, employee(s) operating an abrasive wheel grinder and a CP Can Densifier 200 Machine were not provided with or wearing safety glasses or the equivalent.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.138 A
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.138(a): Employers did not select and require employees to use appropriate hand protection when employees' hands are exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasions; punctures; chemical burns; thermal burns; and harmful temperature extremes: a/ Inside of the Scale House Building and Tire Room, employee(s) handling scrap automobile batteries were not provided with appropriate gloves.
Recent events (3)
- — J (O) $0
- — C (S) $0
- — Z (S) $0
1910.252 B03
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.252(b)(3): Employees exposed to the hazards created by welding, cutting, or brazing operations were not protected by personal protective equipment in accordance with the requirements of 1910.132: Inside of Building #5, the welder was not provided with the following flame retardant clothing: a/ Cap. b/ Jacket. c/ Pants.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.147 C01
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $3,500 · Current $1,600 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative in accordance with 29 CFR 1910.147(c)(4)(i): a/ A lockout tagout program was not developed or implemented prior to the servicing of machinery such as the CD Can Densor 2000.
Recent events (3)
- — J (S) $1600
- — C (S) $3500
- — Z (S) $3500
1910.147 C04 I
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented, and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: Inside of the Scale House Building, written procedures were not developed or utilized for the following machines: a/ Alligator Shear, 480 volts, hydraulics, and gravity. b/ CD Can Densor 2000, 480 volts and hydraulics.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.147 C05 I
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources: Inside of the Scale House Building, lockout/tagout devices were not provided or utilized for the effective isolation of all energy sources for the following machines: a/ Alligator Shear, 480 volts, hydraulics, and gravity. b/ CD Can Densor 2000, 480 volts and hydraulics.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed: Periodic inspections of the specific energy control procedures were not performed for the following machinery: a/ Alligator Shear. b/ CD Can Densor 2000.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.147 C07 I A
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: Authorized employees did not receive training in the following areas: a/ That a lockout/tagout program was required. b/ That specific, written procedures for machinery were required. c/ That lockout devices were required. d/ That periodic inspections of the specific procedures were required.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.147 C07 IV
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(iv): The employer did not certify that employee training has been accomplished and is being kept up to date. The certification shall contain each employee's name and dates of training: a/ Certification and verification that employee training had not been performed was not accomplished.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.215 A04
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $3,500 · Current $500 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one-eighth inch: a/ Inside of the Scale House Building, the work rest belonging to a bench grinder, unknown make, model, or serial number, was positioned approximately three-eighths of an inch away from the abrasive wheel.
Recent events (3)
- — J (O) $500
- — C (S) $3500
- — Z (S) $3500
1910.215 B09
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one-fourth inch: a/ Inside of the Scale House Building, the distance between the safety guard peripheral and the abrasive wheel belonging to a bench grinder, unknown make, model, or serial number, was approximately one-half inch.
Recent events (3)
- — J (O) $0
- — C (S) $0
- — Z (S) $0
1910.303 G01
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $3,500 · Current $500 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment: a/ Inside of the Scale House Building, the space directly below one, live, electrical disconnect and one uncovered, circuit breaker panel was blocked by plastic bags filled with aluminum cans. The electrical disconnect was rated at 480 volts.
Recent events (3)
- — J (O) $500
- — C (S) $3500
- — Z (S) $3500
1910.305 A02 IX
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $3,500 · Current $500 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(ix): All lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lampholder with a guard. Brass shell, paper-lined sockets, or other metal-cased sockets may not be used unless the shell is grounded: a/ Inside of Building #2 a.k.a. Transmission Building, the light bulb inside of a portable lamp was not protected from breakage.
Recent events (3)
- — J (O) $500
- — C (S) $3500
- — Z (S) $3500
1910.305 A02 X
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points: a/ Inside of the Stainless Steel Building, orange, flexible cords used to power a stereo system and portable power tools were not protected from damage. These cords were positioned on the concrete floor. Large quantities of scrap metal were placed over these flexible cords.
Recent events (3)
- — J (O) $0
- — C (S) $0
- — Z (S) $0
1910.305 G01 IV D
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords were used when attached to building surfaces: a/ Inside of the Scale House Building, a green, flexible cord was attached to the structural steel columns and joists. This flexible cord was powering a stereo system.
Recent events (3)
- — J (O) $0
- — C (S) $0
- — Z (S) $0
1910.305 B01 II
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $3,500 · Current $500 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings were not effectively closed: a/ Inside of the Scale House Building, a large, unused opening existed along the left side of a 480 volt, electrical disconnect. The diameter of this opening was approximately one inch. b/ Inside of the Scale House Building, a live, circuit breaker panel box was missing two circuit breakers.
Recent events (3)
- — J (O) $500
- — C (S) $3500
- — Z (S) $3500
1910.305 B02 I
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings were not provided with covers identified for the purpose. If metal covers are used, they shall be grounded: a/ Inside of the Scale House Building, one, live, circuit breaker panel box was not covered.
Recent events (3)
- — J (O) $0
- — C (S) $0
- — Z (S) $0
1910.1200 E01
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $2,100 · Current $500 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): Employers did not develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met: a/ A written hazard communication program was not developed or implemented for employees who handle or are exposed to hazardous materials such as battery acid, grease, and lubricants. Such a program must include how container labeling (f), safety data sheets (g), and employee training (h) are to be managed.
Recent events (3)
- — J (O) $500
- — C (S) $2100
- — Z (S) $2100
1910.1200 E01 I
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1)(i): A list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet (the list may be compiled for the workplace as a whole or for individual work areas); was not prepared: a/ A list of all of the hazardous materials used by employees was not prepared.
Recent events (3)
- — J (O) $0
- — C (S) $0
- — Z (S) $0
1910.1200 F05 I
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container or hazardous chemicals in the workplace was labeled, tagged, or marked with the identity of the hazardous chemical(s) contained therein: a/ Inside of the Stainless Steel Building, one, above ground, 250 gallon tank of diesel fuel was not labeled. b/ Adjacent to Building #5, three totes containing waste oil were not labeled.
Recent events (3)
- — J (O) $0
- — C (S) $0
- — Z (S) $0
1910.1200 F05 II
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings: a/ Inside of the Stainless Steel Building, one, above ground, 250 gallon tank of diesel fuel was not labeled. b/ Adjacent to Building #5, three totes containing waste oil were not labeled.
Recent events (3)
- — J (O) $0
- — C (S) $0
- — Z (S) $0
1910.1200 H01
- Issued
- May 29, 2014
- Abate by
- May 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a/ Employee training in the elements of an effective hazard communication program or the specific hazards related to hazardous materials in use following their initial assignment was not performed.
Recent events (3)
- — J (O) $0
- — C (S) $0
- — Z (S) $0
More inspections at Brock Auto Parts & Sales CO.
View Brock Auto Parts & Sales CO.'s full OSHA safety record →
More inspections in this industry (NAICS 423930)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339756223.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.