RICE LAKE, WI —
OSHA Inspection: QUANEX BUILDING PRODUCTS
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of QUANEX BUILDING PRODUCTS in 311 W COLEMAN STREET, RICE LAKE, WI 54868 (NAICS 337212). OSHA activity number 339758294.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- QUANEX BUILDING PRODUCTS
- Site address
- 311 W COLEMAN STREET
- City
- RICE LAKE
- State
- WI
- ZIP
- 54868
- Mailing
- 311 W COLEMAN STREET, RICE LAKE, WI 54868
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337212
- Employees
- 275
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C06 I B
- Issued
- Jun 19, 2014
- Abate by
- Jul 18, 2014
- Penalty
- Initial $7,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i)(B): The periodic inspection of the energy control procedure was not conducted to correct any deviations or inadequacies identified: (a) OMGA V235 miter saw, COE147: Periodic inspections of the lockout procedures were not conducted at least annually to correct any deviations or inadequacies such as, but not limited to, the kinetic energy of the coast down time.
Recent events (2)
- — I (S) $0
- — Z (S) $7000
1910.147 C06 II
- Issued
- Jun 19, 2014
- Abate by
- Jan 19, 2015
- Penalty
- Initial $0 · Current $4,200
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: (a) OMGA V235 miter saw, COE147: The employer did not produce a certification of the periodic inspection that identified that energy control procedure inspected, the date of the inspection, the employees included in the inspection, and the person performing the inspection.
Recent events (2)
- — I (S) $4200
- — Z (S) $0
1910.147 C06 I C
- Issued
- Jun 19, 2014
- Abate by
- Jan 19, 2015
- Penalty
- Initial $7,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected: (a) OMGA V235 miter saw, COE147: A review of the LOTO procedure was not performed between the inspector and each authorized employee under the energy control procedure being inspected.
Recent events (2)
- — I (S) $0
- — Z (S) $7000
1910.147 C07 I A
- Issued
- Jun 19, 2014
- Abate by
- Jul 18, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation: (a) OMGA V235 miter saw, COE147: The employer did not provide effective training on the recognition of applicable hazardous, the type and magnitude of the energy available, and the methods and means necessary for energy isolation and control on the OMGA V235 miter saw.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 D01
- Issued
- Jun 19, 2014
- Penalty
- Initial $7,000 · Current $4,200 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) OMGA V235 miter saw, COE147: The ingoing nip point on the belt and pulley drive was not effectively guarded.
Recent events (2)
- — I (S) $4200
- — Z (S) $7000
1910.219 E01 I
- Issued
- Jun 19, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o): (a) OMGA V235 miter saw, COE147: The ingoing nip point on the belt and pulley drive was not effectively guarded.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Quanex Building Products
View Quanex Building Products's full OSHA safety record →
More inspections in this industry (NAICS 337212)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339758294.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.