Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: QUANEX BUILDING PRODUCTS

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of QUANEX BUILDING PRODUCTS in 311 W COLEMAN STREET, RICE LAKE, WI 54868 (NAICS 337212). OSHA activity number 339758294.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Quanex Building Products — free Get an email when a new federal OSHA severe-injury report for Quanex Building Products is published. One employer, no account, unsubscribe in one click.
Site address
311 W COLEMAN STREET
City
RICE LAKE
State
WI
ZIP
54868
Mailing
311 W COLEMAN STREET, RICE LAKE, WI 54868
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337212
Employees
275
Ownership type
A

6 citations on file for this inspection.

1910.147 C06 I B

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Jun 19, 2014
Abate by
Jul 18, 2014
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.147(c)(6)(i)(B): The periodic inspection of the energy control procedure was not conducted to correct any deviations or inadequacies identified:  (a) OMGA V235 miter saw, COE147:  Periodic inspections of the lockout procedures were not conducted at least annually to correct any deviations or inadequacies such as, but not limited to, the kinetic energy of the coast down time.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

1910.147 C06 II

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 19, 2014
Abate by
Jan 19, 2015
Penalty
Initial $0 · Current $4,200
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed:    (a) OMGA V235 miter saw, COE147:  The employer did not produce a certification of the periodic inspection that identified that energy control procedure inspected, the date of the inspection, the employees included in the inspection, and the person performing the inspection.
Recent events (2)
  • — I (S) $4200
  • — Z (S) $0

1910.147 C06 I C

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 19, 2014
Abate by
Jan 19, 2015
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected:    (a) OMGA V235 miter saw, COE147:  A review of the LOTO procedure was not performed between the inspector and each authorized employee under the energy control procedure being inspected.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

1910.147 C07 I A

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Jun 19, 2014
Abate by
Jul 18, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:  (a) OMGA V235 miter saw, COE147:  The employer did not provide effective training on the recognition of applicable hazardous, the type and magnitude of the energy available, and the methods and means necessary for energy isolation and control on the OMGA V235 miter saw.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 D01

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 19, 2014
Penalty
Initial $7,000 · Current $4,200 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    (a) OMGA V235 miter saw, COE147:  The ingoing nip point on the belt and pulley drive was not effectively guarded.
Recent events (2)
  • — I (S) $4200
  • — Z (S) $7000

1910.219 E01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 19, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o):  (a) OMGA V235 miter saw, COE147:  The ingoing nip point on the belt and pulley drive was not effectively guarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0