Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MARTECH MEDICAL PRODUCTS, INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MARTECH MEDICAL PRODUCTS, INC in 1500 DELP DRIVE, HARLEYSVILLE, PA 19438 (NAICS 339112). OSHA activity number 339759292.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Martech Medical Products, INC — free Get an email when a new federal OSHA severe-injury report for Martech Medical Products, INC is published. One employer, no account, unsubscribe in one click.
Site address
1500 DELP DRIVE
City
HARLEYSVILLE
State
PA
ZIP
19438
Mailing
1500 DELP DRIVE, HARLEYSVILLE, PA 19438
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339112
Employees
1
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 24, 2014
Abate by
Aug 19, 2014
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  (a)  Throughout Facility - On or about May 2, 2014, specific step by step procedures for the control of hazardous energy were not developed for equipment and machinery requiring service and maintenance.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1910.147 C06 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 24, 2014
Abate by
Aug 19, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  (a)  Throughout Facility - On or about May 2, 2014, the general Lockout/Tagout Procedure was developed in or around 1994 for the control of hazardous energy when performing servicing and maintenance on equipment and machinery, has not been inspected annually.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 24, 2014
Abate by
Aug 19, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:  (a)  Throughout Facility - On or about May 2, 2014, operators of equipment and machinery with hazardous energy sources were not provided with training to the affected level, in that they were not instructed in the purpose and use of the energy control procedure.   (b)  Throughout Facility - On or about May, 2014, all other employees whose work operations are or may be in an area where energy control procedures may be utilized, were not instructed about the procedure, and about the prohibition relating to attempts to restart or re-energize machines or equipment which are locked out or tagged out.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.333 B02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 24, 2014
Abate by
Aug 19, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.333(b)(2)(i): The employer did not maintain a written copy of the procedures outlined in paragraph (b)(2) of 29 CFR 1910.333 and did not make it available for inspection by the Assistant Secretary of Labor and his or her authorized representatives:  (a)  Throughout Facility - On or about May 2, 2014, written procedures for working on or near exposed de-energized parts were not available, neither as a separate procedure or included within the written Energy Control Program.  ABATEMENT NOTES: 1.  The Written Procedures may be in the form of a copy of paragraph (b) of this section. 2.  Lockout and tagging procedures that comply with paragraphs (c) through (f) of 29 CFR 1910.147 will also be deemed to comply with paragraph (b)(2) of this section provided that:      a.  The procedures address the electrical safety hazards covered by this Subpart;      b.  The procedures also incorporate the requi4rements of paragraphs (b)(2)(III)(D) and (b)(2)(iv)(B) of this section.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Martech Medical Products, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339759292.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.