MCCALL, ID —
OSHA Inspection: TIMELESS CONSTRUCTION INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TIMELESS CONSTRUCTION INC. in 210 N 3RD ST., MCCALL, ID 83638 (NAICS 238160). OSHA activity number 339760100.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TIMELESS CONSTRUCTION INC.
- Site address
- 210 N 3RD ST.
- City
- MCCALL
- State
- ID
- ZIP
- 83638
- Mailing
- P.O. BOX 2554, MCCALL, ID 83638
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.501 B01
- Issued
- Jun 3, 2014
- Abate by
- Jun 20, 2014
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) On the roof; an employee was exposed to a fall of 10' 8" from eve to concrete when working on the side wall flashing without benefit of any means of fall protection. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.1053 B01
- Issued
- Jun 3, 2014
- Abate by
- Jun 9, 2014
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to upper landing surfaces, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladders were used to gain access: a) At the eve; employees used the extension ladder which extended approximately 1 foot above the eve line. Note: Abetment certification IS required for this item.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1926.404 B01 III C
- Issued
- Jun 3, 2014
- Abate by
- Jun 13, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(b)(1)(iii)(C): Each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, were not visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage. Equipment found damaged or defective was used: a) The Makita worm drive 7.5 inch skill saw with damaged cord was used exposing employees to a possible electrical shock hazard. Note; Abatement certification IS required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.451 C02 V
- Issued
- Jun 3, 2014
- Abate by
- Jun 13, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2)(v): The employer used forklifts to support scaffold platforms without ensuring that the entire platform was attached to the fork and that the forklift was not moved horizontally while the platform was occupied: a) On site: the job made wooden box was not secured to the forks of the powered industrial truck. Note: Abatement certification IS required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.602 D
- Issued
- Jun 3, 2014
- Abate by
- Jun 13, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.602(d): The employer did not certify that each operator had been trained and evaluated as required by paragraph 29 CFR 1910.178(l): a) The employer did not provide a copy of the powered industrial truck training and evaluation. Note 1: Abatement certification IS required for this item. Note 2: The requirements applicable to construction work under paragraph (d) of this section are identical to those set forth at paragraph (l) of 29 CFR 1910.178.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Timeless Construction INC.
View Timeless Construction INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339760100.