WASHINGTON, DC —
OSHA Inspection: VIC'S MASONRY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of VIC'S MASONRY in 1230 I ST., NE, WASHINGTON, DC 20002 (NAICS 238140). OSHA activity number 339760431.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VIC'S MASONRY
- Site address
- 1230 I ST., NE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20002
- Mailing
- 5114 CRITTENDEN ST., HYATTSVILLE, MD 20781
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 5
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.95 A
- Issued
- Jul 9, 2014
- Penalty
- Initial $1,200 · Current $660 Reduced
General-duty citation text
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition wherever it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact. a) An employee in the front of the structure without head protection was exposed to overhead hazards. on or about 5/7/14.
Recent events (2)
- — I (S) $660
- — Z (S) $1200
1926.451 G01 VII
- Issued
- Jul 9, 2014
- Penalty
- Initial $2,800 · Current $1,540 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) Employees working from the scaffold in the front of the structure did not have appropriate fall protection exposing them to fall hazards of approximately 20 feet, on or about 5/7/14.
Recent events (2)
- — I (S) $1540
- — Z (S) $2800
1926.451 H02 II
- Issued
- Jul 9, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below: a) An employee was working on the ground, below the scaffold without toeboards, exposing him to overhead hazards, on or about 5/7/14.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.454 A
- Issued
- Jul 9, 2014
- Abate by
- Aug 13, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) Employees working from the scaffold had no training in hazards associated with scaffold use, on or about 5/7/14. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1051 A
- Issued
- Jul 9, 2014
- Penalty
- Initial $1,200 · Current $660 Reduced
General-duty citation text
29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided: a) Employees were accessing the scaffold via the window with a break in elevation of 44 inches, on or about 5/7/14.
Recent events (2)
- — I (S) $660
- — Z (S) $1200
1926.1052 C01 II
- Issued
- Jul 9, 2014
- Abate by
- Jul 15, 2014
- Penalty
- Initial $1,600 · Current $880 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: a) Employees using the set of 17 riser stairs to access the second floor were exposed to an open side, on or about 5/7/14. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $880
- — Z (S) $1600
More inspections at Vic'S Masonry
View Vic'S Masonry's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339760431.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.