Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: TAMBOLI HOME IMPROVEMENT

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TAMBOLI HOME IMPROVEMENT in 610 APPLEGATE, WINONA, MS 38967 (NAICS 238990). OSHA activity number 339760860.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tamboli Home Improvement for free Get an email when a new federal OSHA severe-injury report for Tamboli Home Improvement is published. One employer, no account, unsubscribe in one click.
Site address
610 APPLEGATE
City
WINONA
State
MS
ZIP
38967
Mailing
11386 POPE WATERVALLEY RD, COURTLAND, MS 38620
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
3
Ownership type
Private (A)

4 citations on file for this inspection.

1926.403 I02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 25, 2014
Abate by
Jul 8, 2014
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph;    (a) 610 Applegate in Winona, MS - Employees were exposed to live electrical parts when using an extension cord with a 2x4 receptacle box that was missing a cover plate, had an unused opening and was not approved for outside use.
Recent events (2)
  • · I (S) $800
  • · Z (S) $1600

1926.405 G02 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 25, 2014
Abate by
Jul 8, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  (a) 610 Applegate in Winona, MS - Employees were exposed to electrical shock and burns because a flexible extension cord had a defective strain relief on each end.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.1053 B04

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 25, 2014
Abate by
Jul 8, 2014
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:    (a) 610 Applegate in Winona, MS - Employees were exposed to falls from a 12 foot step ladder used as an extension ladder. The step ladder was not fully opened with the spreader bars in the locked position.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

1926.1053 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 25, 2014
Abate by
Jul 8, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step:  (a) 610 Applegate in Winona, MS - An employee was exposed to a fall hazard while standing on the top cap of a 6 foot step ladder.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339760860.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.