ROBBINSVILLE, NJ —
OSHA Inspection: BIND-RITE ROBBINSVILLE LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BIND-RITE ROBBINSVILLE LLC in 1 APPLEGATE DR, ROBBINSVILLE, NJ 08691 (NAICS 323111). OSHA activity number 339762171.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BIND-RITE ROBBINSVILLE LLC
- Site address
- 1 APPLEGATE DR
- City
- ROBBINSVILLE
- State
- NJ
- ZIP
- 08691
- Mailing
- 1 APPLEGATE DR, ROBBINSVILLE, NJ 08691
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323111
- Employees
- 170
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.23 C01
- Issued
- Oct 29, 2014
- Abate by
- Jan 25, 2015
- Penalty
- Initial $3,400 · Current $2,040 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: a) Building 2, Web Department, Press #4: Employees standing on gates were not protected from falling. The gates were located 49 inches above the deck plate, observed on or about 5/9/14. Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (2)
- — I (S) $2040
- — Z (S) $3400
1910.23 E01
- Issued
- Oct 29, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(e)(1): Standard railing(s) did not consist of top rail, intermediate rail and/or posts and/or did not have a vertical height of 42 inches (106.7 cm) nominal from upper surface of top rail to floor, platform runway, or ramp level: a) Building 2, Web Department, Press #4, Elevated platform: While employees are standing on the working platform located on the catwalk of the press they were not protected from falling approximately 7 feet to floor. The existing hand-rail did not extend up to a height that would provide the required fall protection while working from that platform, observed on or about 5/22/14. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.24 B
- Issued
- Oct 29, 2014
- Abate by
- Jan 25, 2015
- Penalty
- Initial $2,550 · Current $1,530 Reduced
General-duty citation text
29 CFR 1910.24(b): Fixed stairs were not provided for access from one structure level to another where operations necessitated regular travel between levels, and for access to operating platforms at any equipment which requires attention routinely during operations: a) Building 2, Web Department, Press #4: Stairs were not provided to the gate platform of the Heidleberg Press. The access plates that were provided measured 7 1/2 inches deep by 6 1/2 inches wide at the widest point. The access plates were used several times a day. Observed on or about 5/9/14. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (2)
- — I (S) $1530
- — Z (S) $2550
1910.147 C04 II
- Issued
- Oct 29, 2014
- Abate by
- Jan 25, 2015
- Penalty
- Initial $4,250 · Current $2,550 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): a) Facility: The employer's procedures did not outline specific steps required by the standard for each specific type of equipment including but not limited to the Heidelberg Harris Press. The procedures did not include details such as but not limited to, how to shut down equipment, where to place the locks and tags for the specific energy of the machine, how to verify zero energy and the steps indicating how to restart the machine, occurred on or about 5/9/14. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (2)
- — I (S) $2550
- — Z (S) $4250
More inspections in this industry (NAICS 323111)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339762171.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.