Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MURRY CONSTRUCTION ASSOCIATES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MURRY CONSTRUCTION ASSOCIATES in 3000 CHARLESTOWN ROAD, LANCASTER, PA 17603 (NAICS 236220). OSHA activity number 339763062.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Murry Construction Associates — free Get an email when a new federal OSHA severe-injury report for Murry Construction Associates is published. One employer, no account, unsubscribe in one click.
Site address
3000 CHARLESTOWN ROAD
City
LANCASTER
State
PA
ZIP
17603
Mailing
22A EAST ROSEVILLE ROAD, LANCASTER, PA 17601
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
9
Ownership type
A

1 citation on file for this inspection.

1926.501 B10

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 3, 2014
Abate by
Jul 30, 2014
Penalty
Initial $1,800 · Current $1,350 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system:  a) Rear Wing Roof Top - Employees (of Geiger Roofing Co., LLC) putting down roof membrane were exposed to falls of approximately eight (8) feet to the lower roof without the use of a fall protection system or safety monitor, on or about May 07, 2014.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1350
  • — Z (S) $1800