Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GEORGIA CAROLINA STUCCO

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of GEORGIA CAROLINA STUCCO in 950 RONALD REAGAN DRIVE 680 INDUSTRIAL PARK DRIVE, EVANS, GA 30809 (NAICS 238140). OSHA activity number 339764953.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Georgia Carolina Stucco — free Get an email when a new federal OSHA severe-injury report for Georgia Carolina Stucco is published. One employer, no account, unsubscribe in one click.
Site address
950 RONALD REAGAN DRIVE 680 INDUSTRIAL PARK DRIVE
City
EVANS
State
GA
ZIP
30809
Mailing
1499 JORDAN ROAD, AUGUSTA, GA 30904
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.451 B01

Repeat Gravity 10 1 instance 4 exposed
Issued
Jun 4, 2014
Abate by
Jun 12, 2014
Penalty
Initial $6,160 · Current $6,160
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports:  On or about 5/8/14 at the front and side of the building; Employees engaged in stucco work on a scaffold system at up to 20 feet 9 inches from the ground level without being fully planked or decked.  The Georgia-Carolina Stucco, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.451(b)(1), which was contained in OSHA inspection number 314209727, citation number 1, item number 3 and was affirmed as a final order on 10/26/12, with respect to a workplace located at 1128 E Robert Toombs Ave, Washington, GA 30673.
Recent events (3)
  • — J (R) $6160
  • — C (R) $6160
  • — Z (R) $6160

1926.451 E01

Repeat Gravity 10 1 instance 4 exposed
Issued
Jun 4, 2014
Penalty
Initial $6,160 · Current $6,160
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access.  On or about 5/8/14 at the front and side of the building; Employees engaged in stucco work on a scaffold system at up to 20 feet 9 inches from the ground level were exposed to a fall hazard. The employer failed to install a ladder for the employees to access the scaffolding.  The Georgia-Carolina Stucco, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.451(e)(1), which was contained in OSHA inspection number 314209727, citation number 1, item number 4 and was affirmed as a final order on 10/26/12, with respect to a workplace located at 1128 E Robert Toombs Ave, Washington, GA 30673.
Recent events (3)
  • — J (R) $6160
  • — C (R) $6160
  • — Z (R) $6160

1926.451 G01

Repeat Gravity 10 1 instance 4 exposed
Issued
Jun 4, 2014
Abate by
Jun 12, 2014
Penalty
Initial $6,160 · Current $6,160
29 CFR 1926.451(g)(1): 29 CFR 1926.451(g)(1):  Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level:  On or about 5/8/14 at the front and side of the building; Employees engaged in stucco work on a scaffold system at up to 20 feet 9 inches from the ground level without guardrails or personal fall arrest systems.  The Georgia-Carolina Stucco, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.451(g)(1), which was contained in OSHA inspection number 314209727, citation number 1, item number 5 and was affirmed as a final order on 10/26/12, with respect to a workplace located at 1128 E Robert Toombs Ave, Washington, GA 30673.
Recent events (3)
  • — J (R) $6160
  • — C (R) $6160
  • — Z (R) $6160

View Georgia Carolina Stucco's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339764953.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.