PARIS, IL —
OSHA Inspection: SEPTIMUS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SEPTIMUS, INC. in 12543 IL HWY 16, PARIS, IL 61944 (NAICS 332111). OSHA activity number 339766073.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SEPTIMUS, INC.
- Site address
- 12543 IL HWY 16
- City
- PARIS
- State
- IL
- ZIP
- 61944
- Mailing
- 12543 IL HWY 16, P.O. BOX 787, PARIS, IL 61944
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332111
- Employees
- 12
- Ownership type
- A
Citations
13 citations on file for this inspection.
1910.37 A03
- Issued
- Oct 8, 2014
- Penalty
- Initial $1,600 · Current $215 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: Septimus, Inc. had employees exposed to bodily injury in the event of an emergency and the need to quickly evacuate the warehouse, due to a blocked exit at the north end of warehouse.
Recent events (3)
- — F (S) $215
- — C (S) $1600
- — Z (S) $1600
1910.37 B02
- Issued
- Oct 8, 2014
- Abate by
- Oct 15, 2014
- Penalty
- Initial $1,600 · Current $215 Reduced
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": Septimus, Inc. had employees exposed to bodily injury in the event of an emergency and the need to quickly evacuate the warehouse, by not having the exit in the Hot Roll Area marked by a sign reading EXIT.
Recent events (3)
- — F (S) $215
- — C (S) $1600
- — Z (S) $1600
1910.147 C04 I
- Issued
- Oct 8, 2014
- Abate by
- Oct 21, 2014
- Penalty
- Initial $2,000 · Current $215 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: Septimus, Inc. had employees perform maintenance operations on pieces of equipment including but not limited to: extruders, hammer mills, augers, dust collectors, and dryers, and the employer did not develop, document, and utilize energy control procedures. These energy control procedures would include the following: a. A specific statement of the intended use of the procedure, b. Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy, c. Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them, and d. Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures.
Recent events (3)
- — F (S) $215
- — C (S) $2000
- — Z (S) $2000
1910.147 C06 I
- Issued
- Oct 8, 2014
- Abate by
- Oct 21, 2014
- Penalty
- Initial $2,000 · Current $215 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: Septimus, Inc. had employees perform maintenance operations on pieces of equipment including but not limited to: extruders, hammer mills, augers, dust collectors, and dryers. The employer did not conduct a periodic inspection of energy control procedures at least annually to ensure that the procedure and the requirements of 1910.147 were being followed. This periodic inspection would include the following: a. The periodic inspection shall be performed by an authorized employee other than the one(s) utilizing the energy control procedure being inspected, b. The periodic inspection shall be conducted to correct any deviations or inadequacies identified, c. Where lockout is used for energy control, the periodic inspection shall include a review, between the inspector and each authorized employee, of that employees responsibilities under the energy control procedure being inspected, d. Where tagout is used for energy control, the periodic inspection shall include a review, between the inspector and each authorized and affected employee, of that employees responsibilities under the energy control procedure being inspected.
Recent events (3)
- — F (S) $215
- — C (S) $2000
- — Z (S) $2000
1910.147 C07 I
- Issued
- Oct 8, 2014
- Abate by
- Oct 23, 2014
- Penalty
- Initial $2,000 · Current $215 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: Septimus, Inc. had employees perform maintenance operations on pieces of equipment including but not limited to: extruders, hammer mills, augers, dust collectors, and dryers, and the employer did not provide lockout training to ensure that the purpose and function of the energy control program was understood by employees. This training would include the following: a. Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control, b. Each affected employee shall be instructed in the purpose and use of the energy control procedure, c. All other employees whose work operations are or may be in an area where energy control procedures may be utilized, shall be instructed about the procedure, and about the prohibition relating to attempts to restart or reenergize machines or equipment which are locked out or tagged out.
Recent events (3)
- — F (S) $215
- — C (S) $2000
- — Z (S) $2000
1910.178 P01
- Issued
- Oct 8, 2014
- Abate by
- Oct 15, 2014
- Penalty
- Initial $2,000 · Current $215 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): Septimus, Inc. had employees operate a CAT powered industrial truck with a safety defect of cut and worn tires, without taking the powered industrial truck out of service until appropriate repairs could be made.
Recent events (3)
- — F (S) $215
- — C (S) $2000
- — Z (S) $2000
1910.219 F03
- Issued
- Oct 8, 2014
- Abate by
- Oct 15, 2014
- Penalty
- Initial $2,000 · Current $215 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: Septimus, Inc. employees were exposed to sprocket wheels and chain: a. Unguarded chain and sprocket on screw auger running under the South baghouse into the bucket elevator; b. Unguarded chain and sprocket on Starpol mixing machine.
Recent events (3)
- — F (S) $215
- — C (S) $2000
- — Z (S) $2000
1910.303 B01
- Issued
- Oct 8, 2014
- Abate by
- Oct 15, 2014
- Penalty
- Initial $2,000 · Current $215 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: Septimus, Inc. had employees exposed to electrical hazards from an electrical extension cord with cut and nicked outer insulation, which provided power to the phone system in the attic.
Recent events (3)
- — F (S) $215
- — C (S) $2000
- — Z (S) $2000
1910.305 G01 IV C
- Issued
- Oct 8, 2014
- Abate by
- Oct 15, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(C): Flexible cords and cables shall not be run through doorways, windows, or similar openings; Septimus, Inc. had employees exposed to electrical hazards from an electrical extension cord running through a doorway to the attic, which provided power to the phone system in the attic
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.303 G02 I
- Issued
- Oct 8, 2014
- Abate by
- Oct 15, 2014
- Penalty
- Initial $2,000 · Current $215 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): Septimus, Inc. had employees exposed to electrical hazards from exposed inner wiring on the Lockout Device for the Extruder on the North Line.
Recent events (3)
- — F (S) $215
- — C (S) $2000
- — Z (S) $2000
1910.305 B01 II
- Issued
- Oct 8, 2014
- Abate by
- Oct 15, 2014
- Penalty
- Initial $2,000 · Current $215 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: Septimus, Inc. had employees exposed to electrical hazards from four openings in electrical cabinets within the Motor Control Room.
Recent events (3)
- — F (S) $215
- — C (S) $2000
- — Z (S) $2000
1910.305 B02 I
- Issued
- Oct 8, 2014
- Abate by
- Oct 15, 2014
- Penalty
- Initial $2,000 · Current $215 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: Septimus, Inc. had employees exposed to electrical hazards from an uncovered electrical outlet in the Plant Manager's office.
Recent events (3)
- — F (S) $215
- — C (S) $2000
- — Z (S) $2000
1910.305 G02 III
- Issued
- Oct 8, 2014
- Abate by
- Oct 15, 2014
- Penalty
- Initial $2,000 · Current $215 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: Septimus, Inc. had employees exposed to electrical hazards from exposed inner wiring on equipment within the facility, due to a lack of strain relief, including but not limited to: Motor running auger (Hammer Mill to Dust Collector).
Recent events (3)
- — F (S) $215
- — C (S) $2000
- — Z (S) $2000
More inspections at Septimus, INC.
View Septimus, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332111)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339766073.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.