BARBOURSVILLE, WV ·
OSHA Inspection: CADCO HEATING & COOLING, INC.
Programmed Related inspection · Safety discipline
At a glance
On , OSHA opened a programmed Related safety inspection of CADCO HEATING & COOLING, INC. in 1356 RIVERVIEW DRIVE, BARBOURSVILLE, WV 25504 (NAICS 238220). OSHA activity number 339766453.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CADCO HEATING & COOLING, INC.
- Site address
- 1356 RIVERVIEW DRIVE
- City
- BARBOURSVILLE
- State
- WV
- ZIP
- 25504
- Mailing
- 2181 WINCHESTER AVENUE, ASHLAND, KY 41101
What kind of inspection was it?
- Inspection type
- Programmed Related (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 12
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1926.501 B01
- Issued
- Jun 18, 2014
- Abate by
- Jun 24, 2014
- Penalty
- Initial $1,760 · Current $880 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. (a) 1356 Riverview Drive, Barboursville WV: Employees were exposed to a fall of approximately 8 feet 10 inches to the lowest portion of the ground, while conducting HVAC work from the rafters. The employees were not protected by a personal fall arrest system, as observed on or about 05/12/2014. (b) 1356 Riverview Drive, Barboursville WV: An employee was installing HVAC ductwork in the rafters of the building. The employee was found descending from the rafters using the guard railing on a Skyjack, Model number 3219, Scissor lift. The employee was exposed to an 8 foot 10 inch fall to the lowest portion of the ground, as observed on or about 05/12/2014. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $880
- · Z (S) $1760
1926.503 A01
- Issued
- Jun 18, 2014
- Abate by
- Jun 24, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: (a) 1356 Riverview Drive, Barboursville WV: The employer did not did not instruct each employee to recognize fall hazards and to utilize fall protection when fall hazards were present, as determined on and at times prior to 05/12/2014. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.20 B02
- Issued
- Jun 18, 2014
- Abate by
- Jun 24, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s). (a) 1356 Riverview Drive, Barboursville WV: The person designated as the competent person did not comply with the requirements of this standard in that they did not identify hazards of the job site, materials and equipment such as but not limited to, ensuring the employees wore fall protection when exposed to a fall hazard, as observed on or about 05/12/2014. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.1053 B13
- Issued
- Jun 18, 2014
- Abate by
- Jun 24, 2014
- Penalty
- Initial $1,760 · Current $880 Reduced
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: (a) 1356 Riverview Drive, Barboursville WV: An employee was installing HVAC duct work in the rafters of the building. The employee was found descending from the rafters using the top step of an 8 foot step ladder, as observed on or about 05/12/2014. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $880
- · Z (S) $1760
1926.1060 A01
- Issued
- Jun 18, 2014
- Abate by
- Jun 24, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1060(a)(1): The employer did not ensure that each employee was trained by a competent person which would enable each employee to recognize hazards related to ladders and stairs, and the procedures to follow to minimize those hazards. (a) 1356 Riverview Drive, Barboursville WV: Employees use a step ladder to access the rafters in order to install HVAC duct work. The employer did not ensure the employees were trained by a competent person on the proper use of the step ladder, as determined on and at times prior to 05/12/2014. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.1200 H03 IV
- Issued
- Jun 18, 2014
- Abate by
- Jun 24, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(3)(iv): The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information: (a) CADCO Heating & Cooling, Inc.: The employees were not provided training on the new SDS (safety data sheets) and label formats on materials used as determined on or about 05/12/2014. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Cadco Heating & Cooling, INC.
View Cadco Heating & Cooling, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238220)
More inspections in WV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339766453.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.