COLUMBUS, OH —
OSHA Inspection: ALEX MASONRY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ALEX MASONRY in 5001 OLENTANGY RIVER ROAD, COLUMBUS, OH 43214 (NAICS 238140). OSHA activity number 339769374.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALEX MASONRY
- Site address
- 5001 OLENTANGY RIVER ROAD
- City
- COLUMBUS
- State
- OH
- ZIP
- 43214
- Mailing
- 1931 WEST BROAD STREET, COLUMBUS, OH 43223
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 E09 IV
- Issued
- Jun 4, 2014
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.451(e)(9)(iv): Cross braces on tubular welded frame scaffolds shall not be used as a means of access or egress. a. On the top of the building where an employee was gaining access to the scaffold, the employee climbed the cross bracing thereby exposing employees to a fall hazard.
Recent events (1)
- — Z (S) $1200
1926.451 G02
- Issued
- Jun 4, 2014
- Abate by
- Jun 24, 2014
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.451(g)(2): Effective September 2, 1997, the employer shall have a competent person determine the feasibility and safety of providing fall protection for employees erecting or dismantling supported scaffolds. Employers are required to provide fall protection for employees erecting or dismantling supported scaffolds where the installation and use of such protection is feasible and does not create a greater hazard. a. On the site where the employer was dismantling a tubular welded frame scaffold, the employer did not make a determination by a competent person as to the feasibility of using a fall protection system thereby exposing employees to a 38 foot fall hazard.
Recent events (1)
- — Z (S) $2000
1926.501 B03
- Issued
- Jun 4, 2014
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.501(b)(3): "Hoist areas." Each employee in a hoist area shall be protected from falling six feet (1.8 m) or more to lower levels by guardrail systems or personal fall arrest systems. If guardrail systems, [or chain, gate, or guardrail] or portions thereof, are removed to facilitate the hoisting operation (e.g., during landing of materials), and an employee must lean through the access opening or out over the edge of the access opening (to receive or guide equipment and materials, for example), that employee shall be protected from fall hazards by a personal fall arrest system. a. On the roof of the building where employees were removing bricks, mortar and other items from the masonry work performed, the employer did not provide fall protection for the employees working at the edge of the roof.
Recent events (1)
- — Z (S) $2800
1926.501 B10
- Issued
- Jun 4, 2014
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.501(b)(10): "Roofing work on Low-slope roofs." Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see Appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted. a. On the roof where employees were cleaning up and walking around, the employer did not install a fall protection system to protect employees on the roof from a fall hazard.
Recent events (1)
- — Z (S) $2800
More inspections at Alex Masonry
View Alex Masonry's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339769374.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.