BYRAM, MS —
OSHA Inspection: UNIVERSAL MAINTENANCE INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of UNIVERSAL MAINTENANCE INC. in 1299 PRISOCK, BYRAM, MS 39272 (NAICS 238990). OSHA activity number 339771024.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNIVERSAL MAINTENANCE INC.
- Site address
- 1299 PRISOCK
- City
- BYRAM
- State
- MS
- ZIP
- 39272
- Mailing
- P. O BOX 104, MURRAYVILLE, GA 30564
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.178 L06
- Issued
- May 29, 2014
- Abate by
- Jun 4, 2014
- Penalty
- Initial $2,380 · Current $1,428 Reduced
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l). (a) Load Out Area - On or about May 16, 2014 four employees were exposed to struck-by hazard when forklift operators were not evaluated and certified for the operation of the equipment.
Recent events (2)
- — I (S) $1428
- — Z (S) $2380
1926.351 B04
- Issued
- May 29, 2014
- Penalty
- Initial $2,975 · Current $1,785 Reduced
General-duty citation text
29 CFR 1926.351(b)(4): Welding cable(s) in use were in need of repair. (a) Load Out Area - On or about May 16, 2014 three employees were exposed to hazard of electric shock when welding with cables that have exposed wires at the clamp, along the cable and at the plug.
Recent events (2)
- — I (S) $1785
- — Z (S) $2975
1926.404 F06
- Issued
- May 29, 2014
- Penalty
- Initial $2,380 · Current $1,428 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous. (a) Load Out Area - On or about May 16, 2014 four employees were exposed to hazard of electric shock when connecting DeWalt grinders to an extension cord that was missing a ground pin.
Recent events (2)
- — I (S) $1428
- — Z (S) $2380
1926.405 G02 III
- Issued
- May 29, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap. (a) Load Out Area - On or about May 16, 2014 four employees were exposed to hazard of electric shock when connecting DeWalt grinders to an extension cord that was spliced at the plug end and covered with tape.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Universal Maintenance INC.
View Universal Maintenance INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238990)
More inspections in MS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339771024.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.