BOULDER, CO ·
OSHA Inspection: BRINKMANN CONSTRUCTORS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BRINKMANN CONSTRUCTORS in 5490 SPINE RD, BOULDER, CO 80301 (NAICS 236116). OSHA activity number 339774945.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BRINKMANN CONSTRUCTORS
- Site address
- 5490 SPINE RD
- City
- BOULDER
- State
- CO
- ZIP
- 80301
- Mailing
- 3855 LEWISTON ST, STE 100, AURORA, CO 80011
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 4
- Ownership type
- Private (A)
Citations
1 citation on file for this inspection.
1926.20 B02
- Issued
- May 29, 2014
- Abate by
- Jun 24, 2014
- Penalty
- Initial $3,500 · Current $2,800 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels were not protected by guardrail systems, safety net system, personal fall arrest system, or other approved alternative fall protection system: (a) Brinkmann Constructors at 5490 Spine Rd, Boulder, CO 80301: On May 20, 2014 the controlling employer did not ensure that subcontractor employees were protected from injury, in that two subcontractor employees framing near the edge of the top floor of building F were not utilizing fall protection. Each worker wore a fall harness; however, their harness was not attached to the lanyard of the fall protection system. A parapet ranging from 18 inches to 30 inches was installed. This condition exposed subcontractor employees to a fall of approximately 30 feet. (b) Brinkmann Constructors at 5490 Spine Rd, Boulder, CO 80301: On May 20, 2014 the controlling employer did not ensure that subcontractor employees were protected from injury, in that two subcontractor employees framing near the edge of the top floor of building F were not utilizing fall protection. A parapet ranging from 18 inches to 30 inches was installed. This condition exposed subcontractor employees to a fall of approximately 30 feet. (c) Brinkmann Constructors at 5490 Spine Rd, Boulder, CO 80301: On May 20, 2014 the controlling employer did not ensure that subcontractor employees were protected from injury, in that one subcontractor employee walked the top plate of an exterior wall on a one-story building without utilizing fall protection. The worker wore a fall harness; however, the harness was not attached to the lanyard of the fall protection system. This condition exposed the subcontractor employee to a fall of approximately 10 feet.
Recent events (2)
- · I (O) $2800
- · Z (S) $3500
More inspections at Brinkmann Constructors
View Brinkmann Constructors's full OSHA safety record →
More inspections in this industry (NAICS 236116)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339774945.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.