Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MARIAN JAGODKA

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MARIAN JAGODKA in 591 CHERRY STREET, WINNETKA, IL 60093 (NAICS 238130). OSHA activity number 339775215.

Watch Marian Jagodka — free Get an email when a new federal OSHA severe-injury report for Marian Jagodka is published. One employer, no account, unsubscribe in one click.
Establishment
MARIAN JAGODKA
Site address
591 CHERRY STREET
City
WINNETKA
State
IL
ZIP
60093
Mailing
8917 MARION AVE., MORTON GROVE, IL 60053
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
3
Ownership type
A

5 citations on file for this inspection.

1926.451 E01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(e)(1): Safe access was not provided to scaffold platforms when the platforms were more than 2 feet (0.6 m) above or below a point of access:           a) Employees were not provided with safe access to scaffolding from which they were required to work at an elevation of approximately 18 feet.          In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • — A (S) $2800
  • — I (S) $1260
  • — Z (S) $2800

1926.451 F06

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6):     a) Scaffolding was erected and used where scaffolding or any conductive materials handled on it was within and might come closer than 10 feet of uninsulated power lines having a voltage rating of less than 50Kv.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
  • — A (S) $2800
  • — I (S) $1260
  • — Z (S) $2800

1926.1053 B12

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(12): Ladders used where the employee or the ladder could contact exposed energized electrical equipment did not have nonconductive side-rails:   a) Portable aluminum extension ladders were provided for employee use where the ladders or the employees could contact electrical service drops (power lines) having a voltage of 120/240.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
  • — A (S) $0
  • — I (S) $0
  • — Z (S) $0

1926.451 F07

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person:      a) The employer did not ensure scaffolding provided for employee use was erected under the supervision and direction of a competent person qualified in scaffolding erection.      In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
  • — A (S) $2000
  • — I (S) $1260
  • — Z (S) $2000

1926.451 G01 I

Serious Gravity 10 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system:           a) Employees were exposed to the hazard of falling approximately 18 feet while working from ladder jack scaffolding without the benefit of fall protection.         In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • — A (S) $2800
  • — I (S) $0
  • — Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339775215.