CAPE VINCENT, NY —
OSHA Inspection: DAVID W. QUICK CONSTRUCTION SERVICES
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DAVID W. QUICK CONSTRUCTION SERVICES in 335 CLUB STREET, CAPE VINCENT, NY 13618 (NAICS 236116). OSHA activity number 339775389.
Where did this inspection happen?
- Establishment
- DAVID W. QUICK CONSTRUCTION SERVICES
- Site address
- 335 CLUB STREET
- City
- CAPE VINCENT
- State
- NY
- ZIP
- 13618
- Mailing
- 28431 STONEY POINT ROAD P.O. BOX 222, CAPE VINCENT, NY 13618
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 5
- Ownership type
- A
Citations
14 citations on file for this inspection.
1926.304 F
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.304(f) Section 4.1.2(b) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws were not equipped with a spreader to prevent material from squeezing the saw or being thrown back on the operator: 29 CFR 1926.304(f) Section 4.1.2(c) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws did not have non-kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: 29 CFR 1926.304(f) Section 5.1.3.3 American National Standards Institute 01.1-1975, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Electrically driven equipment was not equipped with magnetic switches or other devices that will prevent automatic restarting of the machine after a power failure: a) First floor, on or about 5-19-14: Employees were ripping framing lumber on a table saw that was not equipped with a spreader. b) First floor, on or about 5-19-14: Employees were ripping framing lumber on a table saw that was not equipped with non kick-back fingers or "dogs". c) First floor, on or about 5-19-14: Employees were ripping framing lumber on a table saw that was not equipped with a magnetic switch or anti-restart device.
Recent events (3)
- — J (O) $0
- — C (S) $2000
- — Z (S) $2000
1926.304 I01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.304(i)(1): Each circular had-fed ripsaw was not guarded by a hood which completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut: a) First floor, on or about 5-19-14: Employees were ripping framing lumber on a table saw that was not equipped with a hood guard that automatically adjusts to completely enclose the saw blade which protrudes above the table top and/or the piece of material that is being cut.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1926.403 I02 I
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1100.00 Reduced
General-duty citation text
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph: a) Southwest corner of building, on or about 5-19-14: Employees were erecting walls and sheathing within 8-10 inches of an energized service entrance mast/weather head.
Recent events (3)
- — J (S) $1100
- — C (S) $2800
- — Z (S) $2800
1926.950 C01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.950(c)(1): Employee(s) were not permitted to approach and/or take any conductive object(s) without an approved insulating handle closer to exposed energized parts than shown in Table V-1: a) South side of building, southwest corner, on or about 5-19-14: Employees were erecting walls within 3 to 5 feet of energized 4,800 volt primary power lines.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1926.403 B02
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) First floor, on or about 5-19-14: Employees were operating various power tools that were plugged into multiple electrical boxes that were not being used as designed or as "listed and labeled".
Recent events (3)
- — J (S) $0
- — C (S) $1600
- — Z (S) $1600
1926.404 B01 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection: a) First floor, on or about 5-19-14: Employees were operating various power tools that were plugged into multiple receptacles that were not protected by a ground fault circuit interrupter (GFCI).
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1926.404 F06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) First floor, on or about 5-19-14: Employees were operating various power tools that were plugged into a power source that did not have a continuous path to ground due to three missing ground pins.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1926.405 G02 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) First floor, on or about 5-19-14: Employees were using various hand held power tools, powered through a 3-way extension cord with a broken strain relief. b) Elevator pit, on or about 5-19-14: Employees were using an air compressor, powered through an extension cord with a broken strain relief. c) First floor, on or about 5-19-14: Employees were using various hand held power tools, powered through a single extension cord with a broken strain relief.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1926.501 B01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1100.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) East side of building, on or about 5-19-14: Employees were using a stair landing and were not protected from falls, exposing the employees to a fall hazard 9 feet 8 inches.
Recent events (3)
- — J (S) $1100
- — C (S) $2800
- — Z (S) $2800
1926.501 B14
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.501(b)(14): Each employee working on, at, above, or near wall openings (including those with chutes attached), where the outside bottom edge of the wall opening was 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 M) above the walking/working surface, is not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system: a) South wall of building, third floor, on or about 5-19-14: Employees were working in the vicinity of an 8 foot wide door opening and were not protected from falls, exposing the employees to a fall hazard 16 feet 9 inches. b) South wall of building, third floor, on or about 5-19-14: Employees were working in the vicinity of a 36 inch wide window opening and were not protected from falls, exposing the employees to a fall hazard 16 feet 9 inches. c) South wall of building, second floor, on or about 5-19-14: Employees were working in the vicinity of a 6 foot wide door opening and were not protected from falls, exposing the employees to a fall hazard 8 feet 9 inches. d) South wall of building, second floor, on or about 5-19-14: Employees were working in the vicinity of a 3 foot wide window opening with a top rail and no mid rail, exposing the employees to a fall hazard 8 feet 9 inches. e) North wall of building, second floor, on or about 5-19-14: Employees were working in the vicinity of two 6 foot wide door openings, both with top rails and no mid rail, exposing the employees to a fall hazard 8 feet 9 inches to the water below.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1926.1052 C01 I
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a) East side of building, south corner, on or about 5-19-14: Employees were using a stairway without a hand rail on the wall side of the stairs, exposing the employees to a fall hazard of up to 9 feet 8 inches.
Recent events (3)
- — J (S) $0
- — C (S) $1600
- — Z (S) $1600
1926.1052 C01 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: a) East side of building, south corner, on or about 5-19-14: Employees were using a stairway without a stair rail on the open side of the stairs, exposing the employees to a fall hazard of up to 9 feet 8 inches.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1926.1053 B01
- Issued
- Penalty
- Initial $1600.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) Second floor, northwest corner, on or about 5-19-14: Employees were accessing the third floor via a step ladder that was 16 inches below the landing surface, exposing the employees to a fall hazard of 8 feet.
Recent events (3)
- — J (S) $0
- — C (S) $1600
- — Z (S) $1600
1926.1053 B13
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) Second floor, northwest corner, on or about 5-19-14: Employees were accessing the third floor via the top step and top platform of a step ladder.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 236116)
DELAVAN, WI—2026-07-15
TERONOMY BUILDERS, INC.
QUINCY, MA—2026-07-15
UNITEDWOR VM CONTRACTOR CORP
NEWTON, MA—2026-07-14
DELLBROOK CONSTRUCTION, LLC
NEWTON, MA—2026-07-14
GARDEN HOMES
PLAIN CITY, OH—2026-07-09
RUSCILLI CONSTRUCTION
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339775389.