GOWER, MO —
OSHA Inspection: D & D PALLETS*
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of D & D PALLETS* in 9230 NW 316 STREET, GOWER, MO 64454 (NAICS 321920). OSHA activity number 339775983.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- D & D PALLETS*
- Site address
- 9230 NW 316 STREET
- City
- GOWER
- State
- MO
- ZIP
- 64454
- Mailing
- 9230 NW 316 STREET, GOWER, MO 64454
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321920
- Employees
- 38
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Jun 23, 2014
- Abate by
- Jun 27, 2014
- Penalty
- Initial $2,380 · Current $1,666 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) The east end of the green chain was not guarded to prevent employee exposure to an ingoing nip point. (b) The pun due cut up saw was not guarded to prevent employee exposure to an ingoing nip point. Abatement verification is not required for this item.
Recent events (2)
- — I (S) $1666
- — Z (S) $2380
1910.305 B01 I
- Issued
- Jun 23, 2014
- Abate by
- Jun 27, 2014
- Penalty
- Initial $1,785 · Current $1,250 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions: (a) Conductors exiting a 480 volt electrical cabinet #42, were not protected from abrasion since the protective flexible conduit had come loose from its fitting. Abatement verification is not required for this item.
Recent events (2)
- — I (S) $1249.5
- — Z (S) $1785
More inspections at D & D Pallets*
View D & D Pallets*'s full OSHA safety record →
More inspections in this industry (NAICS 321920)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339775983.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.