Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JCG INDUSTRIES INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of JCG INDUSTRIES INC. in 4401 W. BERTEAU AVE., CHICAGO, IL 60641 (NAICS 311615). OSHA activity number 339776296.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch JCG Industries INC. — free Get an email when a new federal OSHA severe-injury report for JCG Industries INC. is published. One employer, no account, unsubscribe in one click.
Establishment
JCG INDUSTRIES INC.
Site address
4401 W. BERTEAU AVE.
City
CHICAGO
State
IL
ZIP
60641
Mailing
4401 W. BERTEAU AVE., CHICAGO, IL 60641
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311615
Employees
900
Ownership type
A

5 citations on file for this inspection.

1910.119 D02 I D

Other-than-serious 1 instance 200 exposed
Issued
Nov 14, 2014
Abate by
Jan 5, 2015
Penalty
Initial $5,000 · Current $1,000 Reduced

Hazardous substances 0170

29 CPR 1910.119(d)(2)(i)(D): Information concerning the technology of the process did not include safe upper and lower limits for such items as temperatures, pressures, flows or compositions:       a) JCG Industries Inc. dba Koch Foods Poultry, Inc. - The employer did not ensure the process safety information, such as safe upper and lower limits for temperatures, pressures and flows was developed and compiled for covered process equipment associated with ammonia refrigeration system, including, but not limited to, the PD-1.
Recent events (2)
  • — I (O) $1000
  • — Z (S) $5000

1910.119 D03 II

Other-than-serious 1 instance 200 exposed
Issued
Nov 14, 2014
Abate by
Jan 5, 2015
Penalty
Initial $5,000 · Current $5,000

Hazardous substances 0170

29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices: The employer did not protect employees from chemical process hazards associated chemical ammonia by documenting that covered process equipment complies with recognized and generally accepted good engineering practices (RAGAGEP):    a) JCG Industries Inc. dba Koch Foods Poultry, Inc. - The employer did not ensure that the U-1 Form (Manufacturer's certificate of compliance covering pressure vessels) was maintained for covered process equipment associated with ammonia refrigeration system including, but not limited to, the PD-1.
Recent events (2)
  • — I (O) $5000
  • — Z (S) $5000

1910.119 E03 III

Deleted Serious Gravity 5 1 instance 200 exposed
Issued
Nov 14, 2014
Abate by
Jan 5, 2015
Penalty
Initial $5,000 · Current $0 Reduced

Hazardous substances 0170

29 CFR 1910.119(e)(3)(iii): The process hazard analysis did not address the engineering and administrative controls applicable to the hazards and their interrelationship.  a) JCG Industries Inc. dba Koch Foods Poultry, Inc. - The employers process hazard analyses did not identify appropriate safe guards such as rigid barriers to protect overhead process equipment including evaporators in the cooler area from impact hazards from powered industrial trucks.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5000

1910.119 J02

Deleted Serious Gravity 5 1 instance 200 exposed
Issued
Nov 14, 2014
Abate by
Jan 5, 2015
Penalty
Initial $5,000 · Current $0 Reduced

Hazardous substances 0170

29 CFR 1910.119(j)(2): Written procedures. The employer did not establish and implement written procedures to maintain the on-going integrity of process equipment.  a) JCG Industries Inc. dba Koch Foods Poultry, Inc. - The employer did not establish the frequency of inspections necessary to maintain the on-going integrity of process equipment, including but not limited, to:   i) The basement machine room FES-6 compressor,  ii) The first floor machine room  FES-2 compressor  iii) The first floor machine room P-1 ammonia pump.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5000

1910.119 E01 IV

Other-than-serious 1 instance 200 exposed
Issued
Nov 14, 2014
Abate by
Nov 20, 2014
Penalty
Initial $0 · Current $0

Hazardous substances 0170

29 CFR 1910.119(e)(1)(iv): The initial process hazard analyses was not completed by May 26, 1997.  a) JCG Industries Inc. dba Koch Foods Poultry, Inc. - The employer did not ensure the initial process hazard analyses was completed by May 26, 1997. The employer's initial process hazards analyses was not completed until September 15-16 2009.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View JCG Industries INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339776296.