MELBOURNE, FL —
OSHA Inspection: HELLER CABINETRY, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of HELLER CABINETRY, INC. in 445 STAN DR., MELBOURNE, FL 32904 (NAICS 337110). OSHA activity number 339777369.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HELLER CABINETRY, INC.
- Site address
- 445 STAN DR.
- City
- MELBOURNE
- State
- FL
- ZIP
- 32904
- Mailing
- 395 STAN DRIVE BLDG A, MELBOURNE, FL 32904
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 15
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.134 C01
- Issued
- Jul 11, 2014
- Abate by
- Aug 27, 2014
- Penalty
- Initial $1,200 · Current $720 Reduced
9010
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a. Granite shop - the employer did not implement a written respiratory protection program when employees were required to wear respirators. During outside dry cutting operations, respirable silica 8-hour time-weighted average sample was 0.585 milligrams per cubic meter of air which was 2.92 times over the permissible exposure limit of 0.2 milligrams per cubic meter of air. Exposure calculations included a zero increment for the 427 minutes not sampled. Violation observed on or about 5/21/14.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1910.134 E01
- Issued
- Jul 11, 2014
- Abate by
- Aug 27, 2014
- Penalty
- Initial $0 · Current $0
9010
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a. Granite shop - the employer did not provide respirator medical evaluation when employees were required to wear respirators. During outside dry cutting operations, respirable silica 8-hour time-weighted average sample was 0.585 milligrams per cubic meter of air which was 2.92 times over the permissible exposure limit of 0.2 milligrams per cubic meter of air. Exposure calculations included a zero increment for the 427 minutes not sampled. Violation observed on or about 5/21/14.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F01
- Issued
- Jul 11, 2014
- Abate by
- Aug 27, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a. Granite shop - the employer did not provide respirator fit testing when employees were required to wear respirators. During outside dry cutting operations, respirable silica 8-hour time-weighted average sample was 0.585 milligrams per cubic meter of air which was 2.92 times over the permissible exposure limit of 0.2 milligrams per cubic meter of air. Exposure calculations included a zero increment for the 427 minutes not sampled. Violation observed on or about 5/21/14.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.242 B
- Issued
- Jul 11, 2014
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a. Granite shop - employee(s) were exposed to struck-by hazards, in that, compressed air used with air blow nozzles connected to an air compressor to clean was at 60 p.s.i. Violation observed on or about 5/21/14.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1910.243 C01
- Issued
- Jul 11, 2014
- Abate by
- Aug 27, 2014
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1910.243(c)(1): Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4)(a): a. Granite shop - during fabrication operations, the employer did not provide a safety guard on a Makita six inch portable grinder and exposed employees to struck by hazards and contacting the unguarded blade. Violation observed on or about 5/21/14.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1910.1000 C
- Issued
- Jul 11, 2014
- Abate by
- Aug 27, 2014
- Penalty
- Initial $1,200 · Current $720 Reduced
9010
General-duty citation text
29 CFR 1910.1000(c): An employee was exposed to (respirable silica) in excess of the 8-hour time weighted average limits of (0.2 milligrams per cubic meter of air) listed in Table Z-3: a. Granite shop - during outside dry cutting operations, respirable silica 8-hour time-weighted average sample was 0.585 milligrams per cubic meter of air which was 2.92 times over the permissible exposure limit of 0.2 milligrams per cubic meter of air. Exposure calculations included a zero increment for the 427 minutes not sampled. Violation observed on or about 5/21/14.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1910.1000 E
- Issued
- Jul 11, 2014
- Abate by
- Aug 27, 2014
- Penalty
- Initial $0 · Current $0
9010
General-duty citation text
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d): a. Granite shop - during outside dry cutting granite fabrication, respirable silica 8-hour time-weighted average sample was 0.585 milligrams per cubic meter of air which was 2.92 times over the permissible exposure limit of 0.2 milligrams per cubic meter of air. Exposure calculations included a zero increment for the 427 minutes not sampled. The employer did not provide engineering controls. Violation observed on or about 5/21/14.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Heller Cabinetry, INC.
View Heller Cabinetry, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 337110)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339777369.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.