PITTSFIELD, MA —
OSHA Inspection: STAR BASE TECHNOLOGIES, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of STAR BASE TECHNOLOGIES, INC. in 343 PECKS ROAD, PITTSFIELD, MA 01201 (NAICS 326199). OSHA activity number 339777583.
Where did this inspection happen?
- Establishment
- STAR BASE TECHNOLOGIES, INC.
- Site address
- 343 PECKS ROAD
- City
- PITTSFIELD
- State
- MA
- ZIP
- 01201
- Mailing
- 343 PECKS ROAD, PITTSFIELD, MA 01201
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 43
- Ownership type
- A
Citations
17 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1400.00 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): Section 5(A)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish to each of his employees employment and a place of employment which were free from recognized hazards that were causing or were likely to cause death or serious physical harm to employees in that employees were exposed to: Crushing hazards as employees were operating powered industrial trucks in a building that did not have seatbelts. Among other methods, one feasible and acceptable method to correct this hazardous condition would be to install seatbelts and keep forklift operators from operating powered industrial trucks without using seatbelts.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.151 C
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: Battery charging area, Star Base Technologies, 343 Pecks Road, Pittsfield, Massachusetts; There was no eyewash or other suitable facilities for quick drenching or flushing of the eyes and body available in the battery charging area where battery maintenance is done.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.178 A06
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates or markings were maintained in a legible condition: Star Base Technologies, 343 Pecks Road, Pittsfield, Massachusetts; The employer did not ensure the label plates on the powered industrial trucks were available and legible therefore the employees were unsure of the ratings of the trucks and were exposed to tipping hazards from overloading. a. Yale forklift in basement did not have a label plate b. Case forklift in workroom did not have a legible label plate
Recent events (2)
- — I (O) $0
- — Z (S) $2800
1910.178 G02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(g)(2): Battery changing and charging installations for industrial trucks were not provided with facilities for flushing and neutralizing spilled electrolyte: Battery charging area, Star Base Technologies, 343 Pecks Road, Pittsfield, Massachusetts; Facilities were not provided for flushing and neutralizing spilled electrolyte where employees perform maintenance on batteries for powered industrial trucks.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.178 P01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): Facility wide, Star Base Technologies, 343 Pecks Road, Pittsfield, Massachusetts; The employer did not remove the green Case forklift from service when it was found that one of the gas tank securing straps was broken, exposing employees to fire and explosion hazards.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.178 Q07
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service: Star Base Technologies, 343 Pecks Road, Pittsfield, Massachusetts; The employer is not performing daily or pre-use checks of powered industrial trucks prior to use.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.179 J02
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $2500.00 Reduced
General-duty citation text
29 CFR 1910.179(j)(2): Overhead cranes and hoists were not being inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, including observation during operation for any defects which might appear between regular inspections: Star Base Technologies, 343 Pecks Road, Pittsfield, Massachusetts; Overhead cranes were not being inspected at intervals between 1 and 12 months as defined in 29 CFR 1910.179(j)(1)(ii).
Recent events (2)
- — I (S) $2500
- — Z (S) $4900
1910.179 J02 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.179(j)(2)(iii): Monthly inspections of hooks, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected, were not performed: Star Base Technologies, 343 Pecks Road, Pittsfield, Massachusetts; Monthly inspections of hooks on cranes and hoists were not completed to include a certification record.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.179 J02 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.179(j)(2)(iv): Monthly inspections of hoist chains, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and an identifier of the chain which was inspected, were not performed: Star Base Technologies, 343 Pecks Road, Pittsfield, Massachusetts; Monthly inspections of hoist chains, with a certification record were not performed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.179 J03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.179(j)(3): A complete periodic inspection of crane(s) had not been conducted in the past 12 months: Star Base Technologies, 343 Pecks Road, Pittsfield, Massachusetts; Complete periodic inspection of overhead cranes and hoists had not been completed in the past 12 months.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.184 E03 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.184(e)(3)(i): A thorough periodic inspection of alloy steel chain slings was not made on a regular basis and/or were done at intervals greater than once every 12 months: Star Base Technologies, 343 Pecks Road, Pittsfield, Massachusetts; The employer did not perform a thorough periodic inspection of the alloy steel chain sling in the previous 12 months.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $1350.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Milling area, Star Base Technologies, 343 Pecks Road, Pittsfield, Massachusetts; Employee in the milling area is exposed to flying chips and point of operation hazards. a. the employee operates the milling machine without guards b. the personal fan in the milling area did not have guards large enough to prevent access to the blades
Recent events (2)
- — I (S) $1350
- — Z (S) $3500
1910.303 B07 I
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $1350.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment. Lower level, Star Base Technologies; On or about May 20, 2014 unused openings in wall hung distribution panels were not effectively closed, but covered with duct tape exposing employees to shock and arc hazards.
Recent events (2)
- — I (S) $1350
- — Z (S) $3500
1910.303 G01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: Lower level by ramp, Star Base Technologies, 343 Pecks Road, Pittsfield, Massachusetts; Access to the 277/480 volt wall hung distribution panel and 6 disconnect switches was blocked by rolling stock and equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 A02 VI
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(a)(2)(vi): Receptacles used on the end of flexible cords were not of the grounding type. Workroom floor, Star Base Technologies, 343 Pecks Road, Pittsfield, Massachusetts; The employer was using two prong extension cords in the facility that did not have grounding pins exposing employees to electric shock hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: Facility wide, Star Base Technologies; On or about March 20, 2014 flexible cords were used in lieu of permanent wiring throughout the facility. a. The bench grinder was plugged into a relocatable power tap being used as an extension cord b. Extension cords were in use throughout the facility, including the basement, to power lighting
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 F05 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings: Workroom floor, Star Base Technologies, 343 Pecks Road, Pittsfield, Massachusetts; Employees were exposed to unknown chemicals in second use containers as the employer did not ensure each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 326199)
ERIE, PA—2026-07-14
CAPLUGS, LLC
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
PETALUMA, CA—2026-07-10
LABCON NORTH AMERICA
KEEWATIN, MN—2026-07-09
111565 - TACKLE TAMER PRODUCTS INC
EAST FLAT ROCK, NC—2026-07-09
161517 - ELKAMET, INC.
More inspections in MA
BELLINGHAM, MA—2026-07-16
BELLINGHAM DEPARTMENT OF PUBLIC WORKS
PLYMOUTH, MA—2026-07-15
TECH-ETCH, INC.
WESTFIELD, MA—2026-07-15
BOISE CASCADE BUILDING MATERIALS DISTRIBUTION, L.L.C.
QUINCY, MA—2026-07-15
UNITEDWOR VM CONTRACTOR CORP
FALL RIVER, MA—2026-07-15
CRESCO LABS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339777583.