HONESDALE, PA —
OSHA Inspection: ESTEMERWALT LUMBER PRODUCTS LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ESTEMERWALT LUMBER PRODUCTS LLC in 505 ADAMS POND RD., HONESDALE, PA 18431 (NAICS 321113). OSHA activity number 339778029.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ESTEMERWALT LUMBER PRODUCTS LLC
- Site address
- 505 ADAMS POND RD.
- City
- HONESDALE
- State
- PA
- ZIP
- 18431
- Mailing
- 505 ADAMS POND RD., HONESDALE, PA 18431
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321113
- Employees
- 20
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.305 G01 IV A
- Issued
- Jul 18, 2014
- Abate by
- Sep 4, 2014
- Penalty
- Initial $1,020 · Current $765 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Planer mill: Flexible cords was used for wiring overhead lights in the planer mill, as observed on or about May 22, 2014. b) Round log lathe: Flexible cord was used for wiring of the speed control unit on the lathe carriage, as observed on or about May 22, 2014. Abatement Certification Required.
Recent events (2)
- — I (S) $765
- — Z (S) $1020
1910.305 G02 III
- Issued
- Jul 18, 2014
- Abate by
- Sep 4, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a) Round log mill: The flexible cord to the saddle notcher motor was not connected so that strain relief was provided, as observed on or about May 22, 2014. Abatement Certification Required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 II
- Issued
- Jul 18, 2014
- Abate by
- Sep 4, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: a) Mill: The employer did not certify that periodic inspections of the energy control procedures had been performed, on or about May 22, 2014. Abatement Certification Required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.147 C07 IV
- Issued
- Jul 18, 2014
- Abate by
- Sep 4, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(iv): The employer did not certify that employee training had been accomplished and kept up to date: a) Mill: The employer did not certify that employee training had been accomplished and kept up to date, on or about May 22, 2014. Abatement Certification Required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Estemerwalt Lumber Products LLC
View Estemerwalt Lumber Products LLC's full OSHA safety record →
More inspections in this industry (NAICS 321113)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339778029.