AMHERST, NY —
OSHA Inspection: MATT C.M. CONTRACTING INCORPORATED
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MATT C.M. CONTRACTING INCORPORATED in 19-27 LONGMEADOW ROAD, AMHERST, NY 14226 (NAICS 238160). OSHA activity number 339779092.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MATT C.M. CONTRACTING INCORPORATED
- Site address
- 19-27 LONGMEADOW ROAD
- City
- AMHERST
- State
- NY
- ZIP
- 14226
- Mailing
- 536 ORIENT STREET, MEDINA, NY 14103
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.21 B02
- Issued
- Jun 10, 2014
- Abate by
- Jul 11, 2014
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a) On or about 05/22/14, on construction site, Apartment Building at Oxford Village Townhomes, 19 -27 Longmeadow Road , Amherst , NY: Employees engaged in construction work including roofing & clean-up were not trained to recognize potential hazards on this type of jobsite, including but not limited to falls from roofs, ladders, skylights, stairs & scaffolds, electrical hazards, unguarded tools/machines, fire hazards, and the need for personal protective equipment to protect them from various hazards. They also were not trained in the applicable OSHA regulations to control or eliminate these hazards. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.95 A
- Issued
- Jun 10, 2014
- Abate by
- Jun 14, 2014
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.95(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided: a) On or about 05/22/14, on the roof of Apartment Building at Oxford Village Townhomes, 19 -27 Longmeadow Road , Amherst , NY: Three employees engaged in roofing work were not provided with, nor wearing eye and head protection while using or working in the vicinity where an air powered Hitachi Coil Nail Gun was being used to fasten roofing shingles. b) On or about 05/22/14, on construction site, Apartment Building at Oxford Village Townhomes, 19 -27 Longmeadow Road , Amherst , NY: Two employees engaged in clean-up work on the ground below the roof were not provided with, nor wearing eye and head protection. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.404 F06
- Issued
- Jun 10, 2014
- Penalty
- Initial $1,020 · Current $510 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) On or about 05/22/14, on the roof construction site of Apartment Building at Oxford Village Townhomes, 19 -27 Longmeadow Road , Amherst , NY: An employee used a Ryobi circular saw to cut plywood. The Saw was connected to 120 volt-ac power via an extension cord which was plugged into a receptacle on a Coleman Powermate 5000 portable generator. The plug on the extension cord lacked a ground prong. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $510
- — Z (S) $1020
1926.416 E01
- Issued
- Jun 10, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) On or about 05/22/14, on the roof construction site of Apartment Building at Oxford Village Townhomes, 19 -27 Longmeadow Road , Amherst , NY: An employee used a Ryobi circular saw to cut plywood. The Saw was connected to 120 volt-ac power via an extension cord which was plugged into a receptacle on a Coleman Powermate 5000 portable generator. The outer sheath of the extension cord was frayed at the female end, exposing the conductors. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01 I
- Issued
- Jun 10, 2014
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) On or about 05/22/14, on the roof construction site, Apartment Building at Oxford Village Townhomes, 19 -27 Longmeadow Road, Amherst, NY: Two ladder jack scaffolds were erected on the north side of the Building. Employees were on the "pick" of each scaffold installing roofing shingles and transporting bundles of the shingles to employees on the roof. The employees were exposed to a fall of approx. 17 ft. to the ground. No personal fall arrest system or other fall protection system was utilized. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.451 E01
- Issued
- Jun 10, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. a) On or about 05/22/14, on the roof construction site, Apartment Building at Oxford Village Townhomes, 19 -27 Longmeadow Road, Amherst, NY: Employees were exposed to a fall of approx. 17 to 20 ft. to the ground while hoisting themselves up a distance of approx. 2 ft. 3 in. from the narrow aluminum "pick" of the ladder jack scaffold to the roof. Direct access to the roof was not provided. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B11
- Issued
- Jun 10, 2014
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 05/22/14, on the roof of Apartment Building at Oxford Village Townhomes, 19 -27 Longmeadow Road , Amherst , NY: Five employees engaged in roofing work were exposed to a fall of approx. 20 foot. No fall protection system was utilized. The roof pitch was 8 in 12. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.1053 B01
- Issued
- Jun 10, 2014
- Penalty
- Initial $1,020 · Current $510 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladders' length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about 05/22/14, on the roof of Apartment Building at Oxford Village Townhomes, 19 -27 Longmeadow Road, Amherst, NY: Two ladder jack scaffolds were erected on the north side of the Building. Employees used an extension ladder to access the "pick" of each scaffold. The employees were exposed to a fall of approx. 17 ft. to the ground because the siderails of an extension ladder used to access the west scaffold from the ground only extended approx. 16 inches above the edge of the pick, and the siderails of an extension ladder used to access the east scaffold from the ground only extended 27 inches above the edge of the pick. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $510
- — Z (S) $1020
More inspections at Matt C.M. Contracting Incorporated
View Matt C.M. Contracting Incorporated's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339779092.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.