FOND DU LAC, WI ·
OSHA Inspection: BRENNER TANK, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BRENNER TANK, LLC in 450 ARLINGTON AVE, FOND DU LAC, WI 54935 (NAICS 336212). OSHA activity number 339779514.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BRENNER TANK, LLC
- Site address
- 450 ARLINGTON AVE
- City
- FOND DU LAC
- State
- WI
- ZIP
- 54935
- Mailing
- 450 ARLINGTON AVE., FOND DU LAC, WI 54935
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336212
- Employees
- 292
- Ownership type
- Private (A)
Citations
1 citation on file for this inspection.
1910.306 B03
- Issued
- Aug 11, 2014
- Abate by
- Sep 30, 2014
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1910.306(b)(3): Limit switch. A limit switch or other device shall be provided to prevent the load block from passing the safe upper limit of travel of any hoisting mechanism: a) On or about May 14, 2014 and prior to this date, employees worked with and around a Pandjiris 1144 Head Director manipulator located in the Aluminum Plant #6 Department, which had been modified to allow the equipment to weld on larger diameter tanks. The employer had relocated the end boom arm hoist bracket and bypassed the limit switch to allow for the boom arm to rise up to higher angles which created cable failure and the boom arm to free fall. Employees were thereby exposed to being struck by the falling boom arm and attached end equipment.
Recent events (3)
- · F (O) $7000
- · C (S) $7000
- · Z (S) $7000
More inspections at Brenner Tank, LLC